CodeCode
FunctionFunction
MainSubMainSub
247Used to clear the OPC drum (membrane 301Used to display the sensor status attached to the
decrease) correction counter. (This simulation is machine.
executed when the OPC drum is replaced.2Used to display the status of the sensors attached
9Used to clear the printer counter and other to the standard cassette and the manual feed tray.
counters. (The counter is cleared after completion (Use SIM 4-2 for the option cassettes.)
of maintenance.)The sensor of an uninstalled cassette is not
10FAX counter data cleardisplayed.
15Used to clear the scanner counter in the network 401Used to check the sensor of the machine manual
scanner mode.feed tray.
251Used to check the operation of the main drive 2Used to adjust the manual paper feed tray paper
(excluding the scanner section) and to check the width detector detection level.
operation of the toner concentration sensor. (The 3The AD conversion value of manual feed width
toner concentration sensor output can be detection is displayed.
monitored.) (To be supported for Ver.00.72 or 411Used to check the document size detection photo
later)sensor.
2Used to make the initial setting of toner 2Used to adjust the detection level of the document
concentration when replacing developer.size photo sensor.
261Used to set whether the job separator is installed 3Used to check the light reception level and the
or not. (Since this cannot be detected by hardware detection level of the original size detection photo
detection, it is set in this simulation.)sensor.
2Used to set whether the automatic detection of 4Used to adjust the detection level of OC 20
paper size is made or not.degrees.
3Used to set the specifications of the auditor. 431Used to set the fusing temperature in 600dpi,
Setting must be made depending on the use 1200dpi, or postcard print.
condition of the auditor.10Used to set the paper feed cycle timing when
5Used to set the count mode of the total counter printing postcards.
and the maintenance counter.441Used to make various setups in each mode of
6Used to set the specifications depending on the process control.
destination.34Used to set the transfer current value in each
10Network scanner trial mode settingmode.
12Used to input the Software Key for E-MAIL RIC.35Used to set the DV-Bias/Grid environment (low
14Used to input the Software Key for the PS temperature) correction temperature.
extension kit.40Used to set the time from the start of the main
18Used to set enable/disable of toner save operation.motor rotation (Ready) to the start of toner supply
22Used to set the specification (language display) for in previous rotation after turning on the power.
the destination.462Used to set the exposure level in each exposure
30Used to set ON/OFF of the heater lamp slow-up mode.
control conforming to the CE mark control.7Used to adjust the shift amount and the inclination
35Used to set whether the same continuous troubles value for each level (1 to 5) of the exposure mode
are displayed as one trouble or the series of (Super Photo).
troubles with SIM 22-4 when the same troubles 9Used to adjust the shift amount and the inclination
occur continuously.value for each level (1 to 5) of the exposure mode
36Used to set whether the machine is stopped or not (Text).
when the maintenance counter life is expired.10Used to adjust the shift amount and the inclination
41Used to set ON/OFF of the automatic value for each level (1 to 5) of the exposure mode
magnification ratio selection (AMS) when setting (Text/Photo).
the binding function. 11Used to adjust the shift amount and the inclination
46Used to set whether to meet with the output value for each level (1 to 5) of the exposure mode
direction of images regardless of the mode when (Photo).
installing the finisher.12FAX exposure level adjustment (1 mode automatic
50Used to set ON/OFF of the black and white adjustment)
reversion function.13FAX exposure level adjustment (Normal mode
57Used to set the model code.individual adjustment)
60Used to set enable/disable of the FAX mode key 14FAX exposure level adjustment (Fine text mode
when FAX is not installed. (When FAX is installed, individual adjustment)
the FAX mode is enabled regardless of this setup.)15FAX exposure level adjustment (Super Fine mode
71In the power save time setting, the pre-heat (pre-individual adjustment)
heat mode setting) and the auto power shut off 16FAX exposure level adjustment (Ultra Fine mode
time can be set to the short time setup (pre-heat: 1 individual adjustment)
min, auto power shut off: 4 min) and the long time 18Used to adjust inclination for each exposure mode.
setup (pre-heat: 15min, auto power shut off: 19Used to set the control method of the exposure
60min).mode.
271Used to set PC/MODEM communication trouble 20Used to set the exposure correction value of SPF/
(U7-00) detection Yes/No.RSPF for OC exposure.
5Used to set the tag number.30Used to set the AE and the limit value in AE (Toner
save).
AR-M236/M276/M237/M277 SIMULATION 8 - 4 |