SW30 No.3 Rotation printSW31 No. 5, No.6 Report output (in reception)
Used to set Enable/Disable of rotation print when the received docu-Used to set whether the communication report table is outputted or not
ment can be printed by rotation.when a reception (excluding confidential reception) is made.
When set to 1, the received document is rotated and printed.Setup is selected from "print inhibition," "all output," and "only in error"
When set to 0, the received document is not rotated.as follows:
Default: 1 (The received document is rotated and printed.)bit5 6
0 0: Print inhibited
SW30 No.4 Department management0 1: All are printed.
Used to set Enable/Disable of FAX using dept. management by the
use of the dept. management function.1 0: Only in error
1 1: Same as "print inhibited."
When set to 1, the department management function is used.Default: 0 0 (Print inhibited)
When set to 0, the department management function is not used.
Default: 0 (The department management function is not used.)SW31 No.7, No.8 Inhibited to use
SW30 No.5 Default data, sender printSW32 No.1 - No.4 Distinctive ring
The function judges TEL or FAX by CI ringing.
Used to set whether the registered sender information and date and
time of transmission are printed at the top of the transmission docu-Default: 0 0 0 0 (OFF)
ment when a document is transmitted through the second line.SW32 No.5 Inhibited to use
When set to 1, date and sender are printed.
SW32 No.6 Index print setup
When set to 0, date and sender are not printed.Used to set whether the index is printed or not when outputting
Default: 1 (Date and sender are printed.)
received documents.
SW30 No.6 Department name notificationWhen set to 1, the index is printed on the received document.
Used to set whether the department name is transmitted as senderWhen set to 0, the index is not printed.
information when the department management function is enabled.
Default: 0 (The index is not printed.)
Default: 0 (OFF)SW32 No.7, No.8 Inhibited to use
SW30 No.7 Date/sender print position setup
SW33 No.1 Page number print setup
Used to set the print position of date and transmitter information on the
transmitted documents.Used to set whether the page number is added to the position where
When set to 1, printed at the top of the document.date and transmitter information are printed. (In memory transmission,
paper number/total number of pages)
When set to 0, added outside the document.When set to 1, the page number is printed.
Default: 0 (Added outside the document.)
When set to 0, the page number is not printed.
SW30 No.8 Report output (in confidential reception)Default: 1 (The page number is printed.)
Used to set whether the communication report table is outputted or not
when a confidential reception is made.SW33 No.2 - No.8 Inhibited to use
When set to 1, the communication report table is printed.SW34 No.1 - No.8 Inhibited to use
When set to 0, the communication report table is not printed.SW35 No.1 Cover function default setup
Default: 1 (Printed)Used to set whether the cover is added or not when transmitting.
SW31 No.1, No.2 Report output (in transmission)When set to 1, the cover is added.
Used to set whether the communication report is outputted or not afterWhen set to 0, the cover is not added.
completion of transmission (excluding sequential broadcasting,Default: 0 (The cover is not added.)
sequential send request, and relay broadcasting).
Setup is selected from "print inhibition," "all output," and "only whenSW35 No.2 Inhibited to use
transmission is failed" as follows:SW35 No.3, No.4 CI delete max. OFF time
Used to set the max. wait time from detection of CI signal pulse (num-bit 1 2
ber of times) to the next CI signal pulse detection. If next Ci signal0 0 : Print inhibited
pulse is not detected within this time, the number of calls up to now is
cleared.0 1 : All are printed.
1 0 : Only when transmission is failed.
The setup items are as follows:1 1 : Not used (Same as "Only when transmission is failed.")
bit3 4
Default: 1 0 (Outputted only when transmission is failed.)00: 5sec
SW31 No.3, No.4 Report output (In broadcast, sequential
0 1: 10sec
send request, and relay broadcast)1 0: 15sec
Used to set whether the communication report table is outputted or not1 1: 20sec
after completion of transmission (sequential broadcasting, sequential
send request, and relay broadcasting).Default: 0 1 (10sec)
SW35 No.5 - No.8 Inhibited to use
Setup is selected from "print inhibition," "all output," and "only the
address to which transmission is failed" as follows:SW36 No.1 - No.8 Inhibited to use
bit3 4
SW37 No.1 - No.8 Inhibited to use
SW38 No.1 - No.4 Pause time setup0 0 : Print inhibited
0 1 : All are printed.
1 0 : Only the address to which transmission is failed.Used to set the pause time.
1 1 : Not used (Same as "Only the address to which The set range is 1 sec to 15 sec by binary input.
transmission is failed")When set to 0, it is the same as 2 sec.
Default: 0 1 (All are printed.)Default: 2sec