Contact Us
Privacy Notice
Shipping & Returns
Search for Manual:  
 
Search
 
Categories
 ACEC
 ACER
 AEG
 AIKO
 AIWA
 AKAI
 ALBA
 ALFATEC
 ALINCO
 ALNO
 ALPINE
 AMSTRAD
 AOC
 APPLE
 ARTHUR MARTIN ELECTROLUX
 ATAG
 ATLAS-ELECTROLUX
 BANG&OLUFSEN
 BARCO
 BAUKNECHT
 BECKER
 BEKO
 BELINEA
 BLAUPUNKT
 BOSCH
 BOSS
 BRANDT
 BRAUN
 BROTHER
 BUSH
 CANON
 CASIO
 CASTOR
 CLARION
 CLATRONIC
 COMMODORE
 COMPAQ
 CORBERO
 CRATE
 CROSSLEE
 CROWN
 CTX
 CURTISS
 DAEWOO
 DECCA
 DENON
 DIORA
 DOMETIC
 DUAL
 ELECTROLUX
 ELEKTRA
 ELEKTRA BREGENZ
 ELEKTRO HELIOS
 ELITE
 ERICSSON
 ESCOM
 FAURE
 FENDER
 FERGUSON
 FINLUX
 FISHER
 FLYMO
 FRIGIDAIRE
 FUNAI
 GELHARD
 GEMINI
 GOODMANS
 GRAETZ
 GRANADA
 GRUNDIG
 HAMEG
 HANSEATIC
 HARMAN
 HARMAN KARDON
 HEWLETT-PACKARD
 HITACHI
 HUSQVARNA
 HYUNDAI
 IAT
 IGNIS
 INFINITY
 INTEGRA
 ITT
 JBL
 JOHN LEWIS
 JUNO-ELECTROLUX
 JVC
 KAWAI
 KENWOOD
 KODAK
 KOERTING
 KORG
 KUPPERSBUSCH
 LADEN
 LG-GOLDSTAR
 LLOYDS
 LOEWE
 LUX
 LUXMAN
 LUXOR
 M-AUDIO
 MACKIE
 MARANTZ
 MARYNEN
 MATSUI
 MATURA
 MAX-FIRE
 MCCULLOCH
 MEDION
 METZ
 MICROVITEC
 MIELE
 MINOLTA
 MITAC
 MITSUBISHI
 MOFFAT
 MOTOROLA
 MTC
 NAD
 NAKAMICHI
 NEC
 NN
 NOKIA
 NORDMENDE
 NUMARK
 OKI
 ONKYO
 OPTIQUEST
 ORION
 OTHERS
 PACE
 PALLADIUM
 PANASONIC
 PARKINSON COWAN
 PARTNER
 PEACOCK
 PERICOM
 PHILIPS
 PIONEER
 POLAR
 POLAROID
 PRIVILEG
 PROGRESS
 QUELLE
 REVOX
 REX-ELECTROLUX
 RFT
 RICOH
 ROADSTAR
 ROLAND
 ROSENLEW
 ROTEL
 SABA
 SALORA
 SAMSON
 SAMSUNG
 SANGEAN
 SANSUI
 SANYO
 SCHNEIDER
 SEG
 SELECO
 SENNHEISER
 SEPPELFRICKE
 SHARP
 SHERWOOD
 SHURE
 SIEMENS
 SILENTIC
 SONY
 TANDBERG
 TAXAN
 TEAC
 TEC
 TECHNICS
 TELEFUNKEN
 TENSAI
 THERMA
 THOMSON
 THORENS
 TORNADO
 TOSHIBA
 TRICITY BENDIX
 TURBO
 UHER
 UNITRA
 UNIVERSUM
 UNKNOWN
 VIEWSONIC
 VOLTA
 VOSS-ELECTROLUX
 VOX
 WATSON
 WEGA
 WHIRLPOOL
 XER
 ZANKER
 ZANUSSI
 ZOPPAS

SHARP CDC5H Repair Manual

$7.99

SHARP CDC5H - It's a complete service manual, and it's in PDF format. It contains circuit diagrams ( schemas ) etc. It also usually contains parts catalog. After placing order we'll send You download instructions on Your email address. See below for delivery information

The manual is available only in language(s): English


Link to manual will be sent on Your email address after You place order.
This product was added to our catalog on Monday 07 May, 2007.
  Reviews  
  Write Review  
  Buy & Download  

Product Reviews
There are currently no reviews for this product.

Other reviews
Aaron Lawrence - 01/02/2008 4 of 5 Stars!
Contains mechanism diagrams, parts lists and schematics for all worldwide versions of DC-X88Z. Also includes remote schematic etc. A few non-essential pages are missing such as specifications. Includes the mechanical and electronic calibration instructions for the tape decks.
Othmar Herbst - 01/13/2008 3 of 5 Stars!
PDF contains : - schematics, but a little un-sharp. - disassembly instructions, accurate drawings - description of test-modes
Patrick Guice - 04/23/2008 5 of 5 Stars!
Phenomal manual great resoulution and very legible. Will become very helpfull in future for parts and service.
Fabian Castle - 08/01/2006 5 of 5 Stars!
Thanks for the excellent service. The manual arrived quickly and in excellent condition. Quality A+++!
matt wilschke - 03/07/2008 5 of 5 Stars!
Essential for popping the top open and cleaning and replacing what needs repalced. One note: the Ornamental Panel is attached with some adhesive as well as screws and faders so don't be shy about prying it open.

Customers who bought this product also purchased
SHARP 10P16S Service Manual
SHARP 10P16S Service Manual
SHARP 115U_OM.pdf Service Manual
SHARP 115U_OM.pdf Service Manual
SHARP 12P17S Service Manual
SHARP 12P17S Service Manual
SHARP 14BN1 Service Manual
SHARP 14BN1 Service Manual
SHARP 14BM CHASSIS Service Manual
SHARP 14BM CHASSIS Service Manual
SHARP 14BN14 Service Manual
SHARP 14BN14 Service Manual

Click to see text excerpt from the manual
CD-C5H,CP-C5H
Y ASPM SCAN: 87.50MHz ? 108.00 MHz.
Y Only RDS signal is memorized by ASPM because RDS signal has PI code and is suitable and convenient for ASPM operation.
ASPM
Comparing field strength, only one strongest RDS station is memorized of all stations (repeater relay stations) that have same
PI code.
Each PI has AFOS list by individually.
Same PI code N freq: differentExa: P1 has f1, f2, f3 (same PTY).
(AFOS) P2 has f4, f5 (same PTY).
PS: same------
PTY: same
[For example]Pickup and memorized to preset CH.
f 1
f 2f 3f 5f 4 f 6f 9f 10
f 7f 8f 11 f 12 f13
P 1 (PI cord)P 2
PS 1 (Station Name)PS 2P 3P 4
PS 3PS 4
Select signals (f1, f5, f7, f10) are memorized in the preset memory by ASPM.
Y If tentative - ASPM operation is repeated intententionally, never memorized (over write) at the same frequecy.
1st time ASPM ? strongest stations of each pi are memorized.
ASPM is not only very usefull for PTY search, but also EON operation.
2nd time ASPM ? 2nd strong stations of each pi are memorized and so on.
PTY search function is equal to FM band search function as a result.
1. Introduction of RDS for CD-C5H
CD-C5H RDS function is equal to adding EON feature to the current CD-C75H RDS.
EON feature is EONNPTY and EONNTI.
Although PTY and TI indicators are separated, PTY contains TI in the PTY items (software) like current PTY search items.
NEWS,AFFAIRS,INFO,ALARM,TI(TTL 17 kinds)
­­
EONNPTYEONNTI
Can select and stand-byCan select and stand-by
EONNPTY and EONNTI are basically stand-by ? receive the desired program of ON station.
2.The difference point from current CD-C75H RDS. (CD-C75H N CD-C5H)
1. PTY item: added TA.TTL 18 kind.
2. Each OTP�, OTA� ind. light up or go out individually.
OTA� ind. doesnOt light up on current model, CD-C75H due to none EONNTI.
3. Added 3 indicators(in FL) due to adding EON feature.
EON: Lights up only during receiving EON data (14A).
TI:During EON-TI stand-by ? Light up
During receiving ON station. ? blink.
PTY: During EON-PTY stanb-by ? Light up
During receiving ON station. ? blink.
4. No adjust type (None adjusting circuit.)
5. Added EON button.
6. Need to change RDS logo due to add EON feature.
7. Added EONNTI, EONNPTY function.
3. Summary of CD-C5H RDSNEON operation
EONNPTY: Select and set the desired OPTY� ? stand-by? switch to ON(other network) Station at the start of desired
PTY automatically ? stay and listen to PTY of ON station ? switch back to TN(This net) station automatically
at the end of PTY(ON) i.e. after changing to another PTY(except AFFAIRS) or cancelling to receive PTY of
ON station midway.
EONNTI:Select and set the OTI� ? stand-by ? switch to ON station at the start of traffic announcement automati
cally ? stay and listen to TA of ON station ? switch back to TN station autmatically at the end of TA(ON).
ie after TA(ON) is over or cancelled to receive TA of ON station midway.
When switching ? TN ON station.
In case of exist 2 more stations having the desired(specified) OPTY� or OTI�, the receiver will select and switch toON station
comparing field strength at the same time. But when the frequency of ON station exists in the preset-memory, then reciver
switches straight to that ON station(CH), without comparing field strength so can make a quick switching from TNNON sta
tion. Preset memory takes priority of switching TNNON station.
therefore ASPM is usefull not only for PTY search but also for rapid EON switching. Anyway CD-C5H EON is basically stand-
by and receiving method, along with the Guidelines for EON implementation.
� 18 �
Shopping Cart more
0 items
Log In
Reviews more
Write ReviewWrite a review on this product!
Payments
PayPal
PayPal
Information
Shipping & Returns
Privacy Notice
Conditions of Use
List of Manuals
Contact Us
What's New? more
RD-XS34SB
RD-XS34SB
Quick Start

$4.99
Current Parse Time: 0.116 s with 39 queries. Queries took 0.014013