MD-X5/X5H/X5W/X7/X7H/X8/X8H/X8W/XV300H/XV300X
MD-X5/X5H/X5W: Places to add/change/correct
MD SECTION (See the MD-X5/MD-X5W service manual, page 16.) (See the MD-X5H service manual, page 20.)
When the combination consisting of the pickup mechanism and the PWB is changed, enter the TEST mode, make a preliminary
automatic adjustment and then a full automatic adjustment. Then store the adjustment data in the EEPROM.
When the EEPROM is replaced, enter the TEST mode and write the data settings into the EEPROM. Then, make a preliminary
automatic adjustment and a full automatic adjustment. Finally, store the adjustment data in the EEPROM.
Y Note
Remove the MD unit for repeir, and after installing it in the set, be dure to reset it and ascertain that reset has been done.
Resetting procedure(1) Unplug the AC cord from the socket, and hold down the RESET button provided at the rear side
for more than 10 seconds.
(2) Once set the TEST MODE (holding down the TEST MODE (X-BASS button) and button
together, press the POWER button), and then turn off power.
EEPROM (IC1402) writing procedure
1. Procedure to replace EEPROM and to write the initialFor MD-X5For MD-X5H/MD-X5W
value of microcomputer in EEPROM
Ambient temperaturecorrectionAmbient temperature correction
(See the MD-X5/MD-X5W service manual, page 28.)
- 0.9 °C ~ + 2.7 °C-0 6 H+ 12.2 °C ~ + 15.8 °C-0 3 H
(See the MD-X5H service manual, page 32.)
(1) Replace EEPROM.+ 2.7 °C ~ + 6.3 °C-0 5 H+ 15.9 °C ~ + 19.6 °C-0 2 H
(2) Refer to the latest EEPROM data list.+ 6.3 °C ~ + 10.0 °C-0 4 H+ 19.7 °C ~ + 23.2 °C-0 1 H
(3) Hold down the button and MD PLAY button, and press the
+ 10.0 °C ~ + 14.5 °C-0 3 H+ 23.2 °C ~ + 26.8 °C? 0 H
POWER button to enter the test mode.
+ 14.5 °C ~ + 18.2 °C-0 2 H+ 26.9 °C ~ + 30.7 °C+0 1 H
When an MD is loaded, "AUT YOBI" will appear.
Press the MD PLAY button.+ 18.2 °C ~ + 22.3 °C-0 1 H+ 30.8 °C ~ + 34.3 °C+0 2 H
(4) Indication of version.+ 22.3 °C ~ + 26.3 °C? 0 H+ 34.4 °C ~ + 37.9 °C+0 3 H
+ 26.3 °C ~ + 30.3 °C+0 1 H
[ t s m e ]
EEPROM version (c to z)+ 30.3 °C ~ + 34.6 °C+0 2 H
Microcomputer ROM version+ 34.6 °C ~ + 39.0 °C+0 3 H
Model code
+ 39.0 °C ~ + 42.8 °C+0 4 H
(5) Press the CD PLAY button 7 times.
[ E E P R O M S E T ]An example: When ambient temperature is 22°C and meadured
(6) Perform the operation shown in the "EEPROM setting modetemperature is 73H
chart", compare the indication with the EEPROM data list, andTemperature setting = 73 H - 01 H
make a setting according to the EEPROM data list, using VOL = 72 H
UP botton or VOL DOWN button.* When the measured temperature fluctuates between
(7) Set the temperature reference value. two values, take lower one (if temperature fluctuates
(Refer to "Temperature reference setting procedure".) between 73H and 72H, take 72H).
(8) The setting must conform to the EEPROM data list.(3) Press the CD PLAY button 7 times.
(9) Press the PRE-EQ button to write the data into the EEPROM.[ E E P R O M S E T ]
(4) Press the MD PLAY button 1 times.(For MD-X5)
[ F o c u s ]
(5) Press the CD PLAY button 4 times.
2. Temperature reference value setting procedure[ T e m p ]
(to be executed at room temperature within 21 to 29°C)(6) Press once the MD PLAY button.
(1) Test mode stop state.[ T E M P ]
[ t s m e ] : Measured temperature, : Temperature setting
(2) Crrect temperature depending on ambient temperature according(7) Set temperature to the value determined above, using the
to the following table.VOL UP or VOL DOWN button.
(8) Press the MD STOP button.
[ T e m p ]
MD-X8/X8H/X8W
MD SECTION (See the MD-X8/MD-X8H/MD-X8W service manual, page 17.)
When the combination consisting of the pickup mechanism and the PWB is changed, enter the TEST mode, make a preliminary
automatic adjustment and then a full automatic adjustment. Then store the adjustment data in the EEPROM.
When the EEPROM is replaced, enter the TEST mode and write the data settings into the EEPROM. Then, make a preliminary
automatic adjustment and a full automatic adjustment. Finally, store the adjustment data in the EEPROM.
Y Note
Remove the MD unit for repeir, and after installing it in the set, be dure to reset it and ascertain that reset has been done.
Resetting procedure(1) Unplug the AC cord from the socket, and hold down the RESET button provided at the rear side
for more than 10 seconds.
(2) Once set the TEST MODE (holding down the TEST MODE (X-BASS button) and button
together, press the POWER button), and then turn off power.
� 2 � |