CHAPTER 5. TEST FUNCTION
1. General4. Test contents
1) This diagnostic program has been developed for diagnosing ma-
chine functions in the field. The program is contained within the[1] Display & Buzzer test
ER-A440S.
The diagnostic program is stored in the external ROM which will1) Key operation
be executed by the CPU (H8/510) which requires the following
diagnostic operations:100TL
a) Proper power supply voltages are mandatory for logic circuits
(+5V, VDD, POFF, +24V).2) Functional description
b) CPU input/output pins, CPU internal logic, CKDC8, MPCA7, sys-Display the following message on the front and the rear display
tem bus and common ROM/RAM must be working properly.boards.
1. 2. 3. 4. 5. 6. 7. 8. 9. 0.
2. Operational procedure
To start the diagnostic program, you must enter the folA decilowing mcomal poi-nt shifts from lower number of digit by one digit (per
mand.200m sec.).
3-digit test item num? ber key in the SRV mode.
Next, display the following segments (for approx. 1 sec.).
The key assignment must be properly set and the ROM and RAM
must be operating properly to go into this mode. This is necessary
because the control jumps to the program area in the SRV mode. 8. 8. 8. 8. 8. 8. 8. 8. 8. 8.A
master reset must be performed before operating the ECR for the first
time. After any option is installed, a program reset is required. When
the master reset or program reset is performed, be sure to check Repeat the theabove two kinds of displays.
printout on the journal paper.Sound a buzzer continuously during test.
Master reset:Turn power on in the SRV? mode and change it
to the SRV mode with the JF key pressed.3) Check items
a) The display must be correctly shown at each position.
Journal print:MASTER RESET ***
Program reset: Turn power on in the SRV? mode and change itb) The luminosity of displays must be uniform and even at each
to the SRV mode.position.
c) Abnormal buzzer sound is not allowed.
Journal print:PRG. RESET ***
4) Test termination
Press any key. The test terminates with the test and message printed
3. Test command list
With the SRV mode and the following test code entry, the test start.1 0 0
CODEDESCRIPTION
100Display & Buzzer test
101Key code & Cashier key test[2] Key code & Cashier key test
102R/J printer test
104Keyboard test1) Key operation
105Mode switch test
106Printer sensor test101TL
108Calendar osckllator test
109SSP test
2) Functional description
110Drawer open sensor test (For standard drawer)Key code, MRS switch state and Cashier code are displayed.
111Drawer open sensor test (For remote drawer)
120Standard RAM test
130Standard ROM test
150Printer dot pulse width adjustment
200Option RAM test
501RS-232 channel 1 Loop back checkKey code
(Not used)
550RS-232 channel 8 Loop back check(Cashier code) |