FU-40SE-S
6) Switch operation ... ........................ (a) On the main unit: All disabled.
............................. (b) On the remote control: All disabled.
7) Abnormal mode detection ... .......... (a) Enabled. When the abnormal mode is activated, it can be canceled with the
............................."Operation selector/OFF " button on the main unit.
.............................When it is canceled, the aging mode operation is restarted from the
.............................beginning.
(4) Monitor mode
1) Outline ... .............................the monitor mode, data is displayed by the LED to facilitate confirmation of theIn
............................. microcomputer operation.
2) Setting procedure ... ............... Turn the power on while holding down the " Operation selector/OFF " button on
............................. the main unit. While holding it down, press the " AUTO" button within five
............................. seconds. A bleep sound is output and the unit enters the monitor mode.
3) Cancellation procedure ... ........ It can be canceled only by unplugging the unit.
4) Display ................................ 8-bit data is displayed in binary with eight LEDs (Filter, AUTO, Silent, Median,
............................. High, Max, Tobacco, Pollen).
LEDFilterAutoSilentMed.HighMax. Tobacco Pollen
Indicator bit76543210
(MSB)(LSB)
5) Display switching ..................... Each time you press the " OFF timer " button on the remote control, the
............................. display switches in the following order.
............................. A pip sounds as a confirmation of switching.
............................. A bleep sounds exceptionally when the display changes from No. F to 0.
DescriptionIndication for
identification
Display No.OFF timerPower Binary display (Filter, Auto, Silent, Clean Cluster
1hr. 4hr.8hr.Med., High, Max., Tabaco, Pollen) sign(Blue)
0Normal displayUsually, a display
1Odor sensor detection value [Vm]
2Odor sensor reference value [Vx]Odor sensor
3Odor sensor contamination value [NY](Green, Orange,
4Saturation reference value [Vx1]Red, Red + Blue)
5Saturation contamination value [SY]
6Dust sensor detection value [H Vm]Dust sensor
beep7Dust sensor reference value [H Vx](Green, Orange,
Red, Red + Blue)
8Dust sensor contamination value [H Y]
9Fan motor airflow notch (0 ~ 4)
AFan motor revolution speed setting value (1/10rpm)
BFan motor revolution speed (1/10rpm)Usually, a display
CFilter time lower (time)(The degree of
DFilter time upper (time)comprehensive dirt)
EDust sensor time lower (time)
FDust sensor time upper (time)
Remarks: ON: OFF
5. Abnormal mode
(1) Outline
In the abnormal mode, the unit detects abnormality or defects of the main unit or circuits with various sensors, and
controls loads and displays abnormalities according to the problem.
For this product, only " abnormal revolution speed of the fan motor " is classified to this mode.
(2) Abnormal revolution speed of the fan motor
1) Outline ... ............................... This mode is activated when the unit detects that the fan motor is locked or the
......................................... connector is opened.
2) Detection time ... .................... In all modes during operation
3) Detection conditions ... .......... When the unit detects [0 rpm] as the revolution speed of the fan motor for 15
............................. consecutive seconds.
4) Abnormality display ... ............ Only the " silent lamp " flashes in a one-second cycle.
............................. All the other LEDs are turned off.
5) Loads control ... ..................... All the loads are immediately turned off and the operation will stop.
6) Cancellation ... ....................... The abnormal mode can be cancelled by pressing the "Operation selector/OFF
............................. " button on the main unit or the " ON/OFF " button on the remote control.
............................. However, with the problem unsolved, the unit enters the same abnormal mode
............................. even if you turn on the unit again.
18 |