SW-D2 No. 1 ~ No. 5 ReservedSW-F1 No. 5 ~ No. 8 Remote operation code figures by external
Set to "0".TEL
SW-D2 No. 6, No. 7 CI off detection timer Remote operation codes can be changes from 0 through 9. If set to
greater than 9, it defaults to 9. The "5" is not changed.
Set the minimum time period of CI signal interruption which affords to
be judged as a CI OFF section.Ex-7(Default: 5)
SW-F2 No. 1 CNG signal detection in standby condition
AB
When setting to "1", the CNG signal detection function during standby
stops.
SW-F2 No. 2, No. 3 Number of CNG signal detection (AM)
Used for detection of CNG in 1 to 4 pulses.400msec2000msec
12
SW-F2 No. 4, No. 5 Number of CNG signal detection (STAND-BY
SW-D2 No. 8 High frequency cut when Caller ID detectingmode)
Used for detection of CNG in 1 to 4 pulses.
When the CALLER ID signal is detected, high frequency is cut by the
line.SW-F2 No. 6 ~ No. 8 Reserved
SW-E1 No. 1 Automatic switching modeSet to "0".
Used to set auto TEL/FAX switching mode or to set the normal faxSW-G1 No. 1 ~ No. 4 Quiet detect time (Used in answering ma-
mode.chine mode)
SW-E1 No. 2, No. 3 Pseudo ringing time at the phone/fax auto-When an answering machine is connected, if a no sound state is
matic switching modedetected for a certain period of time, the machine judges it as a
transmission from a facsimile machine and automatically switches to
Choice is made as to how long to rumble the dummy ringer on
TEL/FAX automatic switching mode.the FAX mode.
SW-G1 No. 5 ~ No. 8 Quiet detect start timing (Used in answering
SW-E1 No. 4 Number of CNG signal detection at the phone/fax
automatic switching modemachine mode)
Inserts a pause before commencing quiet detection.
Used for detection of CNG in one tone or two tones in the TEL/FAX
automatic switching mode.SW-G2 No. 1 ~ No. 8 Reserved
SW-E1 No. 5 CNG detect time at TEL/FAX modeSet to "0".
The switch which sets the time from the start of the CNG detection toSW-G3 No. 1 ~ No. 3 Reserved
the end in the TEL/FAX automatic switching mode. Set to "0".
SW-E1 No. 6 ~ No. 8 Reserved (All models)SW-G3 No. 4 TAD connected
Set to "0".When connecting the answering machine to the extension telephone
jack, set to "1".
SW-E2 No. 1 ~ No. 4 Pseudo ringer sound output level to the line
(For H, A, HK/CN, MY, TH)SW-G3 No. 5, No. 6 Section time of quiet detection.
Used to adjust the sound volume of pseudo ringer to the line (ringThe switch which sets the time from the start of detection function to
back tone) generated on selecting TEL/FAX. Setting is the reducethe end of the function.
level from -5dBm output level.
(Example) If the reduce level is -5dBm, set by binary input "0""1""0""1"SW-G3 No. 7, No. 8 Reserved
Set to "0".
(5), then output level is -10dBm (-5dBm -5dBm)
If the reduce level is -8dBm, set by binary input "1""0""0""0"SW-H1 No. 1 Busy tone detection ON/OFF time (Lower limit).
(8), then output level is -13dBm (-5dBm -8dBm)The initial value of detection is set according to electric condition.
SW-E2 No. 5 ~ No. 8 ReservedThe set value is changed according to the local switch board. (Erro-
neous detection of sound is reduced.)
Set to "0".Normally the upper limit is set to 900 msec, and the lower limit to 150
SW-F1 No. 1, No. 2 DTMF detect timemsec.
Used to set detect time of DTMF (Dual Tone Multi Frequency) used inIf erroneous detection is caused by sound, etc.. adjust the detection
remote reception (5).range.
The lower limit can be set in the range of 350 msec to 150 msec.
The longer the detect time is, the less the error detection is caused by
noises.SW-H1 No. 2 Busy tone detection ON/OFF time (Upper limit).
SW-F1 No. 3 Remote reception (5) detectSimilarly to SW-H1 No. 1, the set value can be varied.
The upper limit can be set in the range of 650 msec to 750 msec.
Used to set the function of remote reception (5). When set to
"1", the remote reception function is disabled.SW-H1 No. 1SW-H1 No. 2Detection range
SW-F1 No. 4 Remote reception00150 msec - 900 msec
(Corresponding to TEL made by GE) P.B.X.01150 msec - 650 msec
"1": Compatible with TEL mode by GE10350 msec - 750 msec
"0": Not compatible11350 msec - 650 msec
AWhen sending (5) for remote reception with a GE manufac-SW-H1 No. 3 Reserved
tured telephone remote reception may not take place because ofSet to "0".
special specifications in their DTMF.
To overcome this, a soft SW is provided to change the modemSW-H1 No. 4 Busy tone continuous sound detect time
setting to allow for remote reception.Set detecting time busy tone for 5 seconds or 10 seconds.
AIf this soft SW is set to "1", other telephone sets may be adversely
affected.