UX-485TH
FO-885TH
Y Soft switch function descriptionSW-A2 No. 8 CNG transmission
When set to "0" , this model allows CNG transmission by pressing the
SW-A1 No. 1 Protect from echoStart key in the key pad dialing mode. When set to "1", CNG transmis-
Used to protect from echo in reception.sion in the key pad dialing mode cannot be performed. In either case.
CNG transmission can be performed in the auto dial mode.
SW-A1 No. 2 Forced 4800BPS reception
SW-A3 No. 1, No. 2 CED tone signal interval
When line conditions warrant that receptions take place at 4800 BPS
repeatedly.For international communication, the 2100Hz CED tone may act as an
echo suppression switch, causing a communication problem.
It may improve the success of receptions by setting at 4800BPS.
Though SW-A3 No. 1 and No. 2 are normally set to 0, this selfing is used
This improves the receiving document quality and reduces handshake
to change the time between the CED tone signal to eliminate the com-
time due to fallback during training.
munication caused by echo.
SW-A1 No. 3 Footer print
TXRX
When set to "1", the date of reception, the sender machine No., and the
page No. are automatically recorded at the end of reception.CED
T
SW-A1 No. 4 Length limitation of copy/send/receive
Used to set the maximum page length.
DIS
To avoid possible paper jam, the page length is normally limited to 0.6
meter for copy or transmit, and 1 meters for receive.
SW-A3 No. 3 MR Coding
It is possible to set it to "No limit" to transmit a long document, such as aMR Coding is enable.
computer print form, etc. (In this case, the receiver must also be set to
no limit.)SW-A3 No. 4 ECM mode
Used to determine ECM mode function. Refer to following table.
SW-A1 No. 5 CSI transmission
(CSI TRANSMISSION) is a switch to set whether the machine sends orSW-A3 No.4 ECM MODE0011
does not send the signal (CSI signal) informing its own telephone No. to
SW-A3 No.5 ECM MMR MODE0101
the remote fax machine when information is received. When "nonsending"
is set, the telephone No. is not output on the remote transmitting ma-CompressionECM MMR modeYesNoNoNo
chine if the remote transmitting machine has the function to display or
ECM MH modeYesYesNoNo
method
print the telephone No. of receiving machine, using this CSI signal.
MR ModeYesYesYesYes
SW-A1 No. 6 DIS receive acknowledgment during G3 transmission
(Depending on remote machine)
Used to make a choice of whether reception of DIS (NSF) is acknowl-
edged after receiving two DISs (NSFs) or receiving one DIS (two NSFs).SW-A3 No. 5 ECM MMR mode
It may be useful for overseas communication to avoid an echo sup-
See SW-A3 No. 4.
pression problem, if set to 1.
SW-A3 No. 6 ~ No. 8 Reserved
SW-A1 No. 7 Non-modulated carrier for V29 transmission mode
Set to "0".
Though transmission of a non-modulated carrier is not required for trans-
mission by the V29 modem according to the CCITT recommendation, SW-A4 No. 1 ~ No. 5 Signal transmission levelit
may be permitted to a send non-modulated carrier before the imageUsed to control the signal transmission level in the range of -0dB to
signal to avoid an echo suppression problem. It may be useful for over--31dB.
seas communication to avoid an echo suppression problem, if set to 1.
SW-A4 No. 6 Protocol monitor (Error print)
SW-A1 No. 8 EOL (End Of Line) detect timer
If set to "1", protocol is printed at communication error.
Used to make a choice of whether to use the 25-second or 13-second
timer for detection of EOL.SW-A4 No. 7 Protocol monitor
This is effective to override communication failures with some facsimileNormally set to "0". If set to "1", communication can be checked, in case
models that have longer EOL detection.of trouble, without using a G3 tester or other tools.
When communication FSK data transmission or reception is made, the
SW-A2 No. 1 ~ No. 4 Modem speed
data is taken into the buffer. When communication is finished, the data is
Used to set the initial modem speed. The default is 9600BPS.analysed and printed out. When data is received with the line monitor
It may be necessary to program it to a slower speed when frequent line(SW-A4 No. 8) set to "1" the reception level is also printed out.
fallback is encountered, in order to save the time required for fallback
procedure.SW-A4 No. 8 Line monitor
Normally set to "0". If set to "1", the transmission speed and the recep-
SW-A2 No. 5 SenderOs information transmit
tion level are displayed on the LCD. Used for line tests.
(SENDEROS INFORMATION TRANSMISSION) is a switch to set the
function to print the content of HEADER PRINT described in the SW-A5 No. 1, No. 2 Digital line equalization setting (Reception)passcode
list at the front end of receiverOs original when original is Line equalization when reception is to be set according to the line sent to thechar-
remote machine.acteristics.
If this switch is set to "NO", the HEADER PRINT is not output at theSetting should be made according to distance between the telephone
receiving machine.and the telephone company central switching station.
SW-A2 No. 6 ReservedSW-A5 No. 3, No. 4 Digital line equalization setting (Transmission)
Set to "0".Line equalization when transmitter is to be set according to the line
characteristics.
SW-A2 No. 7 Communication error treatment in RTN sending mode
Setting should be made according to distance between the telephone
(Reception)
and the telephone company central switching station.
Used to determine communication error treatment when RTN is sent by
occurrence of a received image error in G3 reception. When it is set to
"1", communication error is judged as no error.