1-20
C Setting the Input Configuration
B Adjusting the Color Temperature N COLOR TEMP ADJ Menu
N INPUT CONFIG Menu
Setting Lists in the COLOR TEMP ADJ MenuOverview
This section explains the setting lists displayed in theNoteYou can set up to nine input channels.
To assign D1 serial digital signals
menu.You cannot reset the setting after you press theData pertaining to the input signals are set with theSerial digital signals can be assigned to the slot where
ENTER or Ent button.INPUT CONFIG menu.the BKM-120D is installed.
How to read the setting listsWhen a channel number (1 to 9) is entered with the
Chapter 2 MenuYFor purposes of explanation, each setting list isTo access the MANUAL menu directlynumeric keypad, it is then possible to set which inputTo assign analog composite signalsChapter 2 Menu
preceded by a menu number. These numbers are notWhen the [F2] button is assigned as the short-cut keyconnector on the rear panel will be assigned to that
Analog composite signals can be assigned to the slot
displayed on the screen.to the MANUAL menu, you can directly access thechannel number, and select the type of signal that willwhere the BKM-127W is installed.
For more information about the menu number, see OAboutMANUAL menu that corresponds to the color
be connected.
menu numbers� on page 26(E).
temperature setting (STD/COL1/COL2) set to theTo assign HD serial digital signals
YThe arrow mark (�) refers you to another setting list
image on the screen.HD serial digital signals can be assigned to the slots
that appears after you make the setting, or to anFor details of how to assign the short-cut key, see O [E]Assigning slot and connector numberswhere the BKM-142HD is installed.
operation that is carried out as a result of the setting.Setting the Power-Up Conditions and Data about the Screen
When there is no arrow mark, the menu does not haveDisplay N SYSTEM CONFIG Menu� on page 39(E).Set which input connector on which slot will be
To assign analog component or RGB signals
any sub-list.
assigned to the current channel.Analog component or RGB signals can be assigned to
[B2] PROBE menu
the slot where BKM-129X is installed.
[B] COLOR TEMP ADJ menuSelect the probe for color temperature adjustment.
Select the adjustment method.START: Start adjustment.Assigning the signal type and format
MANUAL... : Set with the MANUAL adjustmentPROBE: Select the probe.The signal type and format which can be assigned to
knob. �[B1]X: Enter the x coordinate.each channel number vary, depending on what
PROBE... : Set using a probe. �[B2]Y: Enter the y coordinate.adaptors are installed in the rear panel.
COPY... : Copy data from elsewhere. �[B3]LOW LIGHT (20IRE): Enter the luminance (cd/m2)
for low light.
[B1] MANUAL menuHIGH LIGHT (100IRE): Enter the luminance (cd/Structure of the INPUT CONFIG Menu
Adjust the gain and bias with the MANUALm2) for high light.
adjustment knob.LOAD REF VALUE: Select the standard settings of
ADJUST... : Adjust the gain and bias. To shiftthe x and y coordinates. �[B21]Level 1Level 2
between gain adjustment and bias adjustment,
press UP/DOWN buttons. Use appropriate knobs[B21] LOAD REF VALUEINPUT CONFIG (1/2)
in each adjustment as described below. After theSelect one of the followings: CH x
YPBPR
adjustment, press the ENTER or Ent button toD65: Use D65 setting (x and y coordinates and FORMAT C1
RGB
confirm the adjusted values.standard luminance). NTSC, PAL
RED: CONTRAST KNOB (Adjust the R gain orD93: Use D93 setting (x and y coordinates and SLOT NOD1-SDI
bias with the CONTRAST knob.)standard luminance). INPUT NOHD-SDI
GREEN: BRIGHT KNOB (Adjust the G gain or EXT SYNC SLOT
BVM-D14H1U/D14H5U/D14H1E/D14H5E/D14H1A/D14H5Abias with the BRIGHT knob.)[B3] COPY menu AUDIO INPUT
COLOR TEMP
BLUE: CHROMA KNOB (Adjust the B gain orSelect one of followings: � The current data, which is
APERTURE VALUE
bias with the CHROMA knob.)used for adjusting, is copied. CHANNEL NAME C 2PROG
LUMINANCE: PHASE KNOB (AdjustSTD: Copy STD data (factory setting: D65).EDIT
luminance with the PHASE knob.)COL1: Copy COL 1 data (factory setting: D93).CAM
COL2: Copy COL 2 data (factory setting: D65).VTR
To reset RED/GREEN/BLUE to the valueD65: Copy the color temperature of D65.NEW NAME
before adjustmentD93: Copy the color temperature of D93.INPUT CONFIG (2/2)
When you are adjusting the gain or bias using the CH x
Note
MANUAL adjustment knobs, you can reset the 1125/60I SYSTEM
The current data which is used for adjusting (selected
setting to the one before adjustment by pressing the H PHASE
corresponding MANUAL adjustment buttonin the INPUT CONFIG menu) is displayed in blue MARKER PHASE
(BVM-D14H5U/D14H5E/D14H5A) or knobletters and you can not select it. MARKER WIDTH
NTSC SET UP
(BVM-D9H5U/D9H5E/D9H5A). YPBPR MATRIX
To reset all of settings at the same time, press the VCR MODE
PHASE button or knob.
34 (E)35 (E) |