Direction correction signal
State of beam landing is affected by the direction in which the monitor is installed. The change of beam landing can be
corrected by flowing the sinusoidal current through the five correction coils as show below.
LCC TOP LEFTLCC TOP RIGHT
ESWNEESWNE
ESWNE
NC Coil
ESWNEESWNE
LCC BOTTOM LEFTLCC BOTTOM RIGHT
In this monitor, the eight different direction correction currents as shown above corresponding to the eight
terrestrial directions are stored as the pattern data in the internal memory so that an appropriate pattern
that corresponds to the installation direction, can be called.
The pattern that is called from the internal memory, is sent from the microprocessor of the monitor to
IC711 where the digital correction data is D/A converted. The DC output signal from the D/A converter
is added in the LCC drive block.
MENU/SET UP/WHITE UNIFORMITY (1/2)The menu for landing correction is shown. The landing
/MANUAL
pattern that corresponds to the terrestrial direction can be
MANUALcalled from the DIRECTION item of the menu. Any
desired pattern can be selected from the following eight
DIRECTIONEASTpatterns.
FINE ADJUST
NS100NORTH, NORTH EAST
TOP LEFT100EAST, SOUTH EAST
TOP RIGHT100
BOTTOM LEFT100SOUTH, SOUTH WEST
BOTTOM RIGHT100WEST, NORTH WEST
RESET100Select an appropriate direction from the eight patterns that
provides most uniform landing over the entire screen.
Menu for landing correction.
BVM-D20F1A/D20F1E/D20F1U/D24E1WA/D24E1WE/D24E1WU6-7 |