3-1-6. Input/Output Level and Impedance3-1-8. Service Mode
Video input/outputAdditional note on adjustment
Phono jack, 1 Vp-p,W , 75Note:After the completion of the all adjustments, cancell the
unbalanced, sync negativeservice mode by either of the following ways.
S video input/output (Hi8 model)
4-pin mini DIN1) Unplug the main power supply and remove the lithium battery.
Luminance signal:(In this case, date and time and menu setting have been set by
1Vp-p, 75W , unbalanced, sync negativeusers are canceled. Perform resetting.)
Chrominance signal:2) After data on page: D and F is restored, select page: 0, address:
0.286Vp-p 75W , unbalanced01, and return the data to 00. And when data on page: 3 is changed,
Audio input/outputreturn the data to the original condition.
Phono jack,
Input: �7.5 dBs, input impedance more1. Test mode setting
than 47 kWSet/release each test mode. Select page: 0, address: 01, and set data:
Output: �7.5 dBs, (at load impedance 47 kW ),01 before setting the data of page D and F.
impedance less than 2.2 kW
Page FAddress 2A
DataFunction
00Normal
3-1-7. Recording Mode (Standard 8/Hi8) switching
Test mode
(Hi8 model)
Various emergency prohibitions and releases
The record mode (Standard 8/Hi8) of this unit switches as shown in
01Drum emergency, capstan emergency, loading motor
the following table. The playback mode (Standard 8/Hi8) switches
emergency, reel emergency, tape top and end, DEW
automaticaly according to the recording mode of the tape played
detection
back.
Tape UsedRecording ModePage DAddress 10
ME
Hi8
Hi8 MPDataFunction
MPStandard 800Normal
01Camera power ON
02VTR power ON
03Camera+VTR power ON
* For page D and F, the data set will be recorded in the nonvolatile
memory by pressing the PAUSE button on the adjusting remote
commander. Take note that, in this case, the test mode will not
be released even if the main power has been turned off (8.4 Vdc).
* Be sure to return this address data to 00 after completing
adjustments/repairs and press the PAUSE button of the adjusting
remote commander. And select page: 0, address: 01, and set data:
00.
5-30 |