CCD-TRV107E/TRV108E/TRV208E/TRV408E
6. White Balance Adjustment (PD-156 board)
Correct the white balance.
If deviated, the reproduction of the LCD screen may degenerate.
ModeVTR stop
SignalNo signal
Measurement PointCheck on LCD screen
Measuring Instrument
Adjustment Page7
Adjustment Address49, 4A
Specified ValueThe LCD screen should not be colored.
Note: Check the white balance only when replacing the following parts. If
necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC5501
Adjusting method:
Order Page Address DataProcedure
100101Set the data.
274960Set the data, and press PAUSE
button.
374A65Set the data, and press PAUSE
button.
4749Check that the LCD screen is not
colored. If not colored, proceed to
step 10.
5749Change the data so that the LCD
screen is not colored.
6749Press PAUSE button.
774AChange the data so that the LCD
screen is not colored.
874APress PAUSE button.
974AIf the LCD screen is colored,
repeat steps 5 to 9.
1000100Set the data.
5-27 |