CCD-TRV107/TRV108/TRV308/TRV408/TRV608
10. Steady Shot Check
(CCD-TRV308/TRV408/TRV608)
Precautions on the Parts Replacement
There are two types of repair parts.
Type A: ENC03JA
Type B: ENC03JB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing, check
the steady shot operation according to the following method.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
SubjectArbitrary
Measurement PointDisplay data of page 1 (Note)
Measuring Instrument Adjustment remote commander
Specified Value2700 to 5100
Note: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1) STEADY SHOT (Menu display) ...................................... ON
2) ZOOM .................................................................... TELE end
Checking method:
Order Page Address DataProcedure
Pitch sensor check
(SI-033 board SE750)
100311Set the data.
21Check that the display data (Note1)
satisfies the specified value.
Yaw sensor check
(SI-033 board SE751)
300312Set the data.
41Check that the display data (Note1)
satisfies the specified value.
Steady shot check
5Move the camcorder, and check
that the steady shot operations
have been performed normally
Processing after Completing Adjustments
Order Page Address DataProcedure
100300Set the data.
5-20 |