DCR-PC101/PC101E
5. PLL f0 & LPF f0 Final Adjustment (VC-284 board)
RadarWRadarW
RadarWRadarWRadarW
ModeVTR stop
SignalNo signal
Measurement PointDisplayed data of page: 3, address:
02 and 03
Measuring Instrument Adjusting remote commander
Adjustment PageC
Adjustment Address1F, 20, 22, 29
Specified value The data of page: 3, address: 02 is O00�
The data of page: 3, address: 03 is O00�
Note 1: Check that the data of page: 0, address: 10 is O00�.
Adjusting method:
Order Page Address DataProcedure
100101
230130 Press PAUSE button.
Check the data changes to
3302O00� within 5 seconds.
(Note 2)
Check the data is O00�.
4303
(Note 2, 3)
500100
Note 2:If check is NG, the machine is defective.
Note 3:If bit value of bit2, bit3, bit4,O1�, adjust- bit5 or bit6 is
ment has errors. For the error contents, see the follow-
ing table. (For the bit values,O5-4. SER refVICEer to
MODE �, O4-3. 3. Bit value discr�.)imination
Bit value of page: 3,
Error contents
address: 03 data
bit2 = 1 or bit 3 =10 fine adjustment is defPLL fective
bit4 = 1 or bit 5 =10 adjustment is defPLL fective
bit6 = 1LPF f0 adjustment is defective
5-53 |