4. White Balance Adjustment (VC-220 board)
Correct the white balance.
If deviated, the reproduction of the EVF screen may degenerate.
ModeCamera
SubjectArbitrary
Measurement PointCheck on EVF screen
Measuring Instrument
Adjustment PageD
Adjustment Address71, 72
Specified Value The EVF screen should not be colored.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 0C, set data: 60, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 3, address: 22, set data: 0B, and press the PAUSE
button.
4) Select page: D, address: 71 and 72, set the data to the initial
value.
Note: Press the PAUSE button each time to set the data.
AddressData
7180
7280
5) Check that the EVF screen is not colored. If colored, change
the data of page: D, address: 71 and 72 so that the EVF screen
is not colored.
Note:To write in the non-volatile memory (EEPROM), press the
PAUSE button each time to set the data.
6) Select page: 3, address: 22, set data: 00, and press the PAUSE
button.
7) Select page: 3, address: 0C, set data: 00, and press the PAUSE
button.
8) Select page: 0, address: 01, and set data: 00.
5-30 |