[SERVICE POSITION TO CHECK THE VTR SECTION]
Connection to Check the VTR Section
To check the VTR section, set the VTR to the "Forced VTR power ON" mode.
Operate the VTR functions using the adjustment remote commander (with the HOLD switch set in the OFF position).
Setting the OForced VTR Power ON� modeExiting the OForced VTR Power ON� mode
1) Select page: 0, address: 01, and set data: 01.1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02, and press2) Select page: D, address: 10, set data: 00, and press
the PAUSE button of the adjustment remotethe PAUSE button of the adjustment remote
commander.commander.
3) Select page: 0, address: 01, and set data: 00.
Note: If the machine malfunctions (the operating mode changes by itself), connect the FK-1000 block,
CF-1000 block.
When you eject the cassette,
connect Pin qa and Pin qs (GND) of
CN1008 on VC-256 board for 1 second.
CN1008
121
AC power
AC IN adaptor
Mechanism deck
Control switch block (FK-1000)
FP-258 flexible board
Battery terminal board
Audio
VC-256
BoardVC-256 boardFFC-295 flexible
flat cable (24P)
Monitor TV
Control switch block
(CF-1000)
Video
A/V out jack
Info lithium battery
(L series)
CPC-jig
(J-6082-521-A)
Adjustment remote
commander (RM-95)
2-10 |