22. AF Laser Axis Check (1)Processing after Completing Adjustments:
Order Page Address DataProcedure
SubjectDark homogeneous subject
1EEF00Set the data.
(1m from the front of the lens)
262300Set the data.
(Note1)
365B00Set the data.
Measurement Point ideo terminal of VAUDIO/VIDEO jack
465C00Set the data.
Measuring Instrument Monitor TV (Under scan mode)
569000Set the data.
Specified ValueTwo or more hologram lines are
669100Set the data.
perfectly within the inspection frame.
(Fig. 6-1-14.)769200Set the data.
The hologram lines can be seen at
869300Set the data.
every outside of the inspection frame.
960100Set the data, and press PAUSE
button.
Note1: Background paper (J-250-130-A) etc. Perform this adjustment in
the dark place.1000100Set the data.
Note2: The data of page: 0, address: 10 must be O00�.
Switch setting:Inspection frame
1) POWER................................................................. MEMORY
2) NIGHT SHOT ..................................................................OFF
3) FOCUS.................................................................. MANUAL
Checking method:
Order Page Address DataProcedure
100101Set the data.
2EEF82Set the data.
362304Set the data.
465BB4 Set the data.
565CB4 Set the data.Fig. 6-1-14.
666600Set the data.
766700Set the data.
8690DB Set the data.
969102Set the data.
10692C0 Set the data.
1169346Set the data.
1260179Set the data, and press PAUSE
button.
1360178Set the data, and press PAUSE
button.
14Check that two or more
hologram lines are perfectly
within the inspection frame.
(Fig. 6-1-14.)
15Check that the hologram lines
can be seen at every outside of
the inspection frame on the
monitor TV screen (the top, the
bottom, the left and the right).
(Fig. 6-1-14.)
6-38 |