DCR-TRV75/TRV75E/TRV80/TRV80E
8. Flange Back Check9. MAX GAIN Adjustment
SubjectSiemens starSetting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
(2.0m from the front of the lens)
(Luminance : approx. 200 lux)low illuminance will not be produced (dark).
Measurement PointCheck operation on TV monitorSubjectClear chart (Approx. 1m from the
front of the lens) Note1
Measuring Instrument
Adjustment PageF
Specified ValueFocused at the TELE end and WIDE
end.Adjustment Address19
Note1: The data of page: 0, address: 10 must be O00�.Note1: Shoot the clear chart with the zoom WIDE end. And adjust the
direction of the camera so that the chart is located in the center of
the screen.
Switch setting:
Note2: The data of page: 0, address: 10 must be O00�.
1) POWER..................................................................Note3:This adjustment should be carried out upon completion of CAMERAOFlange
2) NIGHT .............................................................................Back Adjustment�.OFF
Note4: NTSC model: DCR-TRV75/TRV80
Note2: When the auto focus is ON, the lens can be checked if it is fPAL model:ocused DCR-TRV75E/TRV80E
or not by observing the data on the page 1 of the adjustment remote
commander.Switch setting:
1) Select page: 0, address: 03, and set data: 0F.1) POWER.................................................................. CAMERA
2) Page 1 shows the state of the focus.2) NIGHT SHOT ..................................................................OFF
1 : 00 : XX3) ZOOM ....................................................................WIDE end
Odd: Focused
4) DIGITAL ZOOM (Menu setting) ....................................OFF
Even: Unfocused
Adjusting method:
Checking method:
1) Select page: 6, address: 40, and set data: 01.Order Page Address DataProcedure
2) Select page: 6, address: 41, and set data: 01.100101Set the data.
3) Place the Siemens star 2.0m from the front of the lens.
262C01Set the data.
4) To open the IRIS, decrease the luminous intensity to the364001Set the data.
Siemens star up to a point before noise appear on the image.
5) Shoot the Siemens star with the zoom TELE end.4696Set the following data.
6) Turn on the auto focus.21 (NTSC), 28 (PAL)
7) Check that the lens is focused (Note2).569700Set the data.
8) Select page: 6, address: 21, and set data: 10.
66016FSet the data, and press PAUSE
9) Shoot the Siemens star with the zoom WIDE end.button.
10) Observe the TV monitor and check that the lens is focused.
7602Check that the data changes to
O01�. (Note5)
Processing after Completing Adjustments:
1) Select page: 6, address: 21, and set data: 00.Note5: The adjustment data will be automatically input to page: F, address:
2) Select page: 6, address: 40, and set data: 00.
19.
3) Select page: 6, address: 41, and set data: 00.
4) Select page: 0, address: 03, and set data: 00.Processing after Completing Adjustments
Order Page Address DataProcedure
162C00Set the data.
264000Set the data.
369600Set the data.
469700Set the data.
560100Set the data, and press PAUSE
button.
600100Set the data.
6-26 |