1-4. CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of OVIDEO SYSTEM ADJUSTMENT� are
satisfied.
1. HALL Adjustment
For detecting the position of the lens iris, adjust the hall AMP gain
and offset.
ModeSTILL
SubjectArbitrary
Measurement PointDisplay data of page 1 (Note1)
Measuring Instrument Adjustment remote commander
Adjustment PageF
Adjustment Address2E, 2F, 34, 35
Specified Value12 to 16 during IRIS OPEN
76 to 7A during IRIS CLOSE
Note 1:Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
Display data
Note 2:Check that the data of page: 6, address: 02 is O00�. If not, turn the
power of the unit OFF/ON.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 94, and set data: 14.
3) Select page: 6, address: 95, and set data: 78.
4) Select page: 6, address: 01, set data: 6D, and press the PAUSE
button of the adjustment remote commander. (The HALL
adjustment is performed and the adjustment data is stored in
page: F, address: 2E, 2F, 34 and 35.)
5) Select page: 6, address: 02, and check that the data is O01�.
6) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
Checking method:
1) Select page: 0, address: 03, and set data: 03.
2) Select page: 6, address: 01, set data: 01, and press the PAUSE
button.
3) Select page: 1, and check that the display data (Note1) during
IRIS OPEN satisfies the specified value.
4) Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
5) Select page: 1, and check that the display data during IRIS
CLOSE satisfies the specified value.
Processing after Completing Adjustments:
1) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2) Select page: 6, address: 94, and set data: 00.
3) Select page: 6, address: 95, and set data: 00.
4) Select page: 0, address: 01, and set data: 00.
5) Select page: 0, address: 03, and set data: 00.
5-19 |