SELF-DIAGNOSIS FUNCTION : Added portion.
4.SELF-DIAGNOSIS CODE TABLE (Refer to page 9)
: Changed portion.
Self-diagnosis Code
Block DetailedSymptom/StateCorrection
Function Code
Repaired by:
C31 30FG fault when starting capstan.Load the tape again, and perform operations from the beginning.
C31 40FG fault when starting drum.Load the tape again, and perform operations from the beginning.
C31 42FG fault during normal drum operLoad the taations.pe again, and perform operations from the beginning.
C31 97Mechanical position fault.Load the tape again, and perform operations from the beginning.
C31 98Mechanical position fault.Load the tape again, and perform operations from the beginning.
C31 99Mechanical position fault.Load the tape again, and perform operations from the beginning.
C32 10LOAD direction loading motor time-Remove the battery or power cable, connect, and perform
out.operations from the beginning.
C32 11UNLOAD direction loading motorRemove the battery or power cable, connect, and perform
time-out.operations from the beginning.
T reel side tape slacking whenRemove the battery or power cable, connect, and perform
C32 20unloading.operations from the beginning.
Winding S reel fault when countingRemove the battery or power cable, connect, and perform
C32 21the rest of tape.operations from the beginning.
Remove the battery or power cable, connect, and perform
C32 22T reel fault.operations from the beginning.
Remove the battery or power cable, connect, and perform
C32 23S reel fault.operations from the beginning.
C32 24T reel fault.Remove the battery or power cable, connect, and perform
operations from the beginning.
C32 30FG fault when starting capstan.Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
C32 40FG fault when starting drumoperations from the beginning.
FG fault during normal drumRemove the battery or power cable, connect, and perform
C32 42operationsoperations from the beginning.
Remove the battery or power cable, connect, and perform
C32 97Mechanical position fault.operations from the beginning.
C32 98Mechanical position fault.Remove the battery or power cable, connect, and perform
operations from the beginning.
C32 99Mechanical position fault.Remove the battery or power cable, connect, and perform
operations from the beginning.
Inspect the lens block focus reset sensor (Pin wg of LA-026 board)
E61 00Difficult to adjust focuswhen focusing is performed when the control dial is rotated in the
(Cannot initialize focus.)focus manual mode, and the focus motor drive circuit (IC140 of
LA-026 board) when the focusing is not performed.
N 2 N |