(2) Select O2. Drive Manual Operation� by pressing the 2 OR�
DVD SECTION
button on the remote commander. The screen will appear as
shown.
8-1. GENERAL DESCRIPTION
The IOP measurement allows you to make diagnosis and adjustmentDrive Manual Operation
simply by using the remote commander and monitor TV. The
instructions, diagnosis results, etc. are given on the on-scr1. Servo Controleen display
(OSD).2. Track/Layer Jump
3. Manual Adjustment
Be sure to execute the IOP measurement when a BU (Base Unit) is
4. Tray Aging Mode
replaced.
5. MIRR time adjust
0. Return to top Menu
8-2. HOW TO ENTER TEST MODE
While pressing the x and A buttons simultaneously, turn (3) Select O3. Manual Adjustment� by pressing the 3 OR� button
VOLUME + with the DVD player in power on.on the remote commander. The screen will appear as shown.
The Test Mode starts, then the menu shown below will be displayed
on the TV screen.Manual Adjust
* The display of the OModel Name� of the ORemocon Diagnosis
1. Track Balance Adjust:
Menu� change with the model and the destination. Refer to below
2. Track Gain Adjust:
on the model name.
3. Focus Balance Adjust:
DZ110 : DSX1
4. Focus Gain Adjust:
DZ111 : DSX1�
5. Eq boost Adjust:
DZ120 : DSX1+6. Iop:
DZ120K : DSX1K7. TRV. Level:
8. S curve(FE) Level:
Remocon Diagnosis Menu
9. RFL(PI) Level:
0. MIRR Time:
0. External Chip Check
1. Servo Parameter Check
o O Change Value
2. Drive Manual Operation[RETURN] Return to previous menu
3. Emergency History Check
4. Version Information
(4)Select O6.IOP� by pressing the 6 OR� button on the remote
commander.
*1
Model Name: DSX1_ XX
(5) Wait until a hexadecimal number appear.
IF-con: Ver. XX.XX (XXXX)
Syscon: Ver.X.XXX
Manual Adjust
*1: Changes depending on destination
1. Track Balance Adjust:
The menu above is the Remocon Diagnosis Menu screen which
2. Track Gain Adjust:
consists of five main functions. At the bottom of the menu screen, the3. Focus Balance Adjust:
model name and IF-con version. To exit from the Test Mode, press4. Focus Gain Adjust:
the power button on the remote commander.5. Eq Boost Adjust:
6. Iop. 5B:
8-3. EXECUTING IOP MEASUREMENT7. TRV. Level:
8. S curve(FE) Level:
In order to execute IOP measurement, the following standard
9. RFL(PI) Level:
procedures must be followed.
0. MIRR Time:
(1) In power on, while pressing the x and A buttonsChange Value
simultaneously, turn VOLUME + .[0] Return to previous menu
Remocon Diagnosis Menu
(6) Convert each data from hexadecimal to decimal using
0. External Chip Check conversion table.
1. Servo Parameter Check
2. Drive Manual Operation
(7) Please find the label on the rear of the BU (Base Unit).
3. Emergency History Check
The default IOP value is written in the label.
4. Version information
(8) Subtract between these two values.
*1
Model Name : DSX1_ XX
IF-con: Ver. XX.XX (XXXX)(9) If the remainder is smaller than 93 (decimal), then it is OK.
Syscon: Ver. X.XXX However if the value is higher than 93, then the BU is defective
and need to be change.
*1: Changes depending on destination
(10) Press the RETURN OR� button to return back to previous
menu.
(11) Press the 0 OR� button to return to Top Menu and power
off the DVD Player.