SAFETY CHECK-OUT
Laser component in this product is capable of emitting radiation
exceeding the limit for Class 1.
After correcting the original service problem, perform the following
safety checks before releasing the set to the customer:
This appliance is classifCheck the antenna terminals, metal trim, metallized knobs,ied as screws,
a CLASS 1 LASER product.and all other exposed metal parts for AC leakage. Check leakage as
The CLASS 1 LASER described below.
PRODUCT MARKING is
located on the rear exteriorLEAKA. GE
The AC leakage from any exposed metal part to earth Ground and
from all exposed metal parts to any exposed metal part having a
return to chassis, must not exceed 0.5 mA (500 microampers).
Leakage current can be measured by any one of three methods.
1. A commercial leakage tester, such as the Simpson 229 or RCA
WT-540A. Follow the manufacturers instructions to use these
instruments.
2. A battery-operated AC milliammeter. The Data Precision 245
This cautiondigital multimeter is suitable for this job.
label is located3. Measuring the voltage drop across a resistor by means of a
inside the unit. VOM or battery-operated AC voltmeter. The limit indication
is 0.75 V, so analog meters must have an accurate low-voltage
scale. The Simpson 250 and Sanwa SH-63Trd are examples of
a passive VOM that is suitable. Nearly all battery operated
digital multimeters that have a 2V AC range are suitable. (See
Fig. A)
To Exposed Metal
Parts on Set
CAUTION
AC
Use of controls or adjustments or performance of procedures
0.15?Fvoltmeter
1.5k&
other than those specified herein may result in hazardous
(0.75V)
radiation exposure.
Notes on chip component replacement
Never reuse a disconnected chip component.
Earth Ground
Y Notice that the minus side of a tantalum capacitor may be
damaged by heat.Fig. A. Using an AC voltmeter to check AC leakage.
Flexible Circuit Board Repairing
Keep the temperature of soldering iron arNOound 270CTE OF REPLACING THE DVD BOARD
during repairing.When replacing the DVD board, since the adjustment value is not
Y Do not touch the soldering iron on the same conductor of theset up correctly, Drive Auto Adjustment cant be performed.
circuit board (within 3 times).In this case, initialize Memory in the following procedures.
Y Be careful not to apply force on the conductor when soldering
or unsoldering.Procedure:
1.Starting test mode. (See page 12)
2.Press the [2] key of the remote commander, and set the DRIVE
MANUAL OPERATION. (See page 18)
3.Press the [6] key of the remote commander, and set the 6. Memory
Check. (See page 20)
4.Press the [CLEAR] key of the remote commander, and initialize
Memory.
SAFETY-RELATED COMPONENT WARNING!!ATTENTION AU COMPOSANT AYANT RAPPORT
� LA S?CURIT?!
COMPONENTS IDENTIFIED BY MARK 0 OR DOTTED LINE WITHLES COMPOSANTS IDENTIF?S PAR UNE MARQUE 0 SUR LES
MARK 0 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTSDIAGRAMMES SCH?MATIQUES ET LA LISTE DES PIéCES SONT
LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESECRITIQUES POUR LA S?CURIT? DE FONCTIONNEMENT. NE
COMPONENTS WITH SONY PARTS WHOSE PART NUMBERSREMPLACER CES COMPOSANTS QUE PAR DES PIéSES SONY
APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTSDONT LES NUM?ROS SONT DONN?S DANS CE MANUEL OU
PUBLISHED BY SONY.DANS LES SUPP?MENTS PUBLI?S PAR SONY.