18. Auto loop filter offset adjust44. 500 track jump reverse
19. Auto focus offset adjustLayer Jump Check
20. Auto focus gain adjust45. Layer jump (L0 ? L1)
21. Auto focus offset adjust46. Layer jump (L1 ? L0)
22. EQ boost adjust47. All servo stop
23. Auto LFO Adjust
24. Auto track gain adjust2. DRIVE MANUAL OPERATION
Search CheckNote: This mode is used for design, and not used in service fundamen-
25. 32Tj forwardtally.
26. 32Tj reverse
27. 500Tj forwardOn the Test Mode Menu screen, press the [2] key on the remote
28. 500Tj reversecommander, and the Operation Menu will be displayed. For the
29. All servo stopmanual operation, each servo on/off control and adjustment can be
executed manually.
1-3. DVD-DL (dual layer)
Press the [3] key on the remote commander and insert a DVD dual## Drive Manual Operation ##
layer disc following the message. Then the adjustment will be madeOperation Menu
through the steps below, then adjusted values will be written to the 1. Disc Type
EEPROM. 2. Servo Control
3. Track/Layer Jump
DVD Dual Layer Disc Adjustment Steps: 4. Non EEPROM Write Adjust
1. Sled tilt reset 5. EEPROM Write Adjust
2. Disc check memory DL 6. Memory Check
3. Wait 500 msec 7. Disc Check Memory
4. Set disc type DL 8. Error Rate Display
5. LD on 9. SACD Water Mark
6. Spindle start
7. Wait 1 secExit: RETURN
Layer 1 Adjust
8. Focus servo on 0In using the manual operation menu, take care of the following
9. Auto track offset adjustpoints. These commands do not provide protection, thus requiring
10. CLVA oncorrect operation. The sector address or time code field is displayed
11. Wait 500 msecwhen a disc is loaded.
12. Tracking on
13. Wait 500 msecNote:
14. Sled on1. Set correctly the disc type to be used on the Disc Type screen.
15. Check CLV lock2. In case of an alarm, immediatelx button to stop they press the
servo operation, and pr[POWER]ess the button to turn the power
16. Auto loop filter offset adjust, Auto focus adjustoff.
17. Auto focus gain adjust
18. Auto focus offset adjust
19. EQ boost adjustBasic operation:
20. Auto loop filter offset adjust
(controllable from front panel or remote commander)
21. Auto Track Gain Adjust[POWER]:Power OFF (release the Test Mode)
Search Check x:Servo stop
22. 32 track jump forward
A:Stop and eject/Loading
23. 32 track jump reverse[RETURN]:Return to Operation Menu or Test
24. 500 track jump forward
25. 500 track jump reverseMode Menu
[ PREV]., [NEXT ]> :Transition between sub modes of menu
Layer 0 Adjust[1] to [9], [10/0]:Selection of menu items
26. Focus jump (L1 t L0)
Cursor o / O:Increase/Decrease in manually
27. Auto track offset adjust L0adjusted value
28. CLVA on
29. Wait 500 msec
30. Tracking on
31. Wait 500 msec
32. Sled on
33. Check CLV lock
34. Auto focus filter offset adjust
35. Auto Focus Adjust
36. Auto focus gain adjust
37. Auto focus offset adjust
38. EQ boost adjust
39. Auto Loop Filter Offset
40. Auto track gain adjust
Search Check
41. 32 track jump forward
42. 32 track jump reverse
43. 500 track jump forward
22 |