Section 3
Replacement of Main Parts (HDC-950)
3-1. Replacing the CCD Unit3. Remove the four hexagon-socket bolts, remove the
four spring washers, and remove the front panel
nassembly.
Never remove or install the CCD unit with the power
turned on. Because touching internal harness to the cabinet
or other printed circuit boards during replacement causes
shorts or electric hazards.
Prior to replacement, be sure to disconnect the optical
cable or the cable connected at the DC IN connector in
addition to turning off power switch.
1. Remove the inside panel and outside panel. (Refer toSpring
washers
Section 1-4 of the Installation and Maintenance
Manual.)
2. Loosen the four screws of front assembly, and remove
the front assembly.
Front panel assembly
Hexagon-socket bolts
(3 x 8)
4. Disconnect the harness connector from the connector
of CCD unit, loosen the two fixing screws of the filter
disk unit, and remove the filter disk unit.
B3 x 10
(with stopper)
Fixing screw of the filter
disk unit (with stopper)
Filter disk unit
Connector
B3 x 10
(with stopper)Front assemblyFixing screw of the filter
disk unit (with stopper)Harness connector
HDC-900/950 MM3-1 (E) |