Min. Value: 000
Max. Value: 040
Recommended Value: 015
16.3.VIDEO ALIGNMENTS
Switch the program to colour bar test pattern. Press GREEN button to access this group of item. Select
the parameter by pressing up/down buttons. Adjust the parameter by pressing left/right buttons. Store
the settings by pressing OK button.
WdR, WdG, WdB: WHITE BALANCE ADJUSTMENT
Apply WHITE test pattern via RF. Adjust all analog functions to medium level and set WdR to 86, WdG
to 84, WdB to 80, if neede d. Use colour analyser and monitor the colour temperature (X,Y) on colour
analyser. Select WdR and WdB by pressing up/down buttons and change the values by Left/Right
buttons till the following values are read:
X=285?10
Y=293?10 on the colour analyser.
CuR, CuG, CuB
Set the values of these items as 64 (constant).
YDFP
Enter a PAL B/G colour and black -white bar test pattern via RF. Adjust Y -Delay for PAL till the colour
transients on the colour bar of the pattern become as sharper and colours between transients do not
mix with each other as possible.
Min. Value: -07
Max. Value: 001
Recommended Value: -05
AGC
Apply PAL BG signal, VHF-3 Channel -12 and 60dBuV signal level. Adjust AGC (Automatic Gain
Control) item by pressing Left/Right butt ons till the voltage at AGC point (pin1 of the tuner) becomes 3.0
volts.
Min. Value: 000
Max. Value: 031
Recommended Value: 016
TLAN
Text language is set. Options are W-T, W-E, W, E. W -T will be selected.
APS
The option of APS ( Automatic Program Searching) item are ON and OFF. In order to active APS
installation procedure when TV is turned for the very first time, select ON. Inorder to start TV without
APS installation procedure, select OFF.
T_T
This item is used for the Tuner selection. The options are SAM for SAMSUNG, THO for THOMSON,
SIE for SIEMENS, MK2 and MK3 for PHILIPS MP2/MP3, ALP for ALPS and TEC for Tecnisat. Select
THO.
T_P
This item is also used for the Tuner selection. The options are MK2, SAM, THO, TEM. MK2 for
PHILIPS, SAM for SAMSUNG, THO for THOMSON and TEM for TEMIC. Select SAM.
YDFS
Enter a SECAM B/G colour and black-white bar test pattern via RF. Adjust Y-Delay SECAM till the
colour transients on the colour bar of the pattern become as sharper and colours between tra nsients do
not mix with each other as possible.
Min. Value: -07