Whirlpool EuropeAKZ 493/IX28.05.2004 / Page 3
SER VICECustomer Service8585 493 01000Doc. No: 4812 725 18449
Technical data
Failure codes
ProductFailureFailure TypeTest
TypeCode
AllF01Temperature ProbeFirst check probe connection. If ok, disconnect the probe
and measure its resistance (1000W + 3.75 x Temp
ambient). If value is in range, change Antares / Capricorn.
AllF02Temperature ErrorCheck heating elements insulation (disconnect each
heating element and check each terminal for continuity to
GROUND). If there is no continuity, change Antares /
Capricorn.
AllF03A.M. EEPROMReplace Capricorn or if applicable reprogram Antares
EEPROM using SAM. If the problem persists, change
Antares.
CapricornF04W.I.S.P. ProtocolFirst check connection between Capricorn and Scales. If
onlyconnection is ok, connect a new Capricorn to the Scales
and check if the appliance works correctly. Otherwise
change Scales.
PyroF05Door LatchFirst unplug the appliance, wait at least 10sec then
reconnect. Verify that latch system works correctly (door
has to be closed, motor has to run). If this happens, check
the connection between Antares and door latch system. If
it is ok, check micro switch functionality (door switch open
if the door is open and latch switch open if the door is
unlocked). If switches are ok, then change Antares.
PyroF06Door ClosureFirst check connection between Antares and door latch
system. If it is ok, check door switch functionality (open
circuit if the door is open, closed circuit if the door is
closed). If switch is ok, then change Antares.
AllF07Communication UI/AMFirst check connection between Antares / Capricorn &
User Interface. If connection is ok, connect a new User
Interface to the Antares / Capricorn and check if the
appliance works correctly. In this case change the User
Interface on the appliance. Otherwise change the Antares
/ Capricorn.
TADF08UI EEPROMChange G2 Smart.
TADF09CommunicationFirst check connection between Antares & User
G2SMART/AntaresInterface. If connection is ok, connect a new G2SMART
to the Antares and check if the appliance works correctly.
In this case change the G2SMART on the appliance.
Otherwise change the Antares
PyroF10Primary grillFirst check grill connections. If it is ok, disconnect the
heating element and check the resistance between the
terminals (approx. 22W? 3W ). If the value is in range,
change Antares.
TADF11CommunicationFirst check connection between G2 and TEX. If
G2SMART/TEXconnection is ok, connect a new TEX to the G2SMART
and check if the appliance works correctly. Otherwise
change G2SMART |