e) Making the settings relating to the lighting of buttons when the
same signal is assigned to more than one cross-point button:
Select the mode of button lighting to be used when one of the buttons
to which the same signal has been assigned is pressed.
MODE1: Of the buttons to which the same signal has been assigned,
only the button of the smallest number lights. (Factory default
setting)
MODE2: All the buttons to which the same signal has been assigned
light.
f) LAST X function setting for FlexiPad snapshot recall: Select
whether or not to disable the LAST X function, activated on each of
the M/E banks, when using the FlexiPad to recall a snapshot, by
entering 00 then pressing.
ENBL: Enable the OLAST X� function. (Factory default setting)
DSBL: Disable the OLAST X� function.
g) Fader lever operation settings: Select the way in which the lever
position and the progress of the transition are related.
MODE1: The transition progression is linear, according to the
position of the lever. (Factory default setting)
MODE2: The lever position and the transition progression are related
by an S-curve. The transition is more gradual when the lever is
close to the end of its travel.
h) Setting for bus tally indicator operation: Select whether the bus
tally indicator at the right hand end of each bus is used as a bus tally
or as an indicator for the video process function.
TALLY: Use as a bus tally.
V-PROC: Use as an indicator for the video process function. That is
to say, the bus tally indicator lights when video processing for the
signal selected on this bus is on.
i) Setting for the LAST X button in the numeric keypad section:
Select whether to enable or disable the LAST X function.
ENBL: Enable the LAST X function. (Factory default setting)
DSBL: Disable the LAST X function.
Chapter 14 Setup14-79 |