Adaptation to different types of gas
Injectors replacement
? Remove the pan supports.
? Remove the burner's caps and crowns.
? With a socket spanner 7 unscrew and remove
the injectors (Fig. 7), and replace them with the
ones required for the type of gas in use.
? Reassemble the parts, following the same
procedure backwards.
? Replace the rating label (placed near the
gas supply pipe) with the relevant one for the
new type of gas supply. You can find thisFO 0392Fig. 7
label in the package of the injectors supplied
with the appliance.
Should the feeding gas pressure be different or
variable compared with the required pressure,
an appropriate pressure adjuster must be fitted
on the gas supply pipe, in compliance with the
rules in force.
Fig. 8
Adjustment of minimum
level By-pass screw
To adjust the minimum level of the burners,
proceed as follows:
?Light the burner.
By-pass diameters
?Turn the knob on the minimum position.
?Remove the knob. BurnerO By-pass
?With a thin screwdriver, adjust the by-pass screwin 1/100
of mm.
(Fig. 8). If changing from natural gas to LPG, completely Auxiliary28
tighten clockwise the screw, until a small regular flame Semi-rapid32
is obtained.
?Finally check the flame does not go out when Ultra-rapid56
quickly turning the knob from the maximum position
to the minimum position.
This procedure can easily be carried out, anyhow the hob
has been positioned or built in the working top.
51 |