The hood may be used as an exhaust or filter hood. Since these instructionsyellow/green = ground ? blue = neutral (N) ? brown = line (L)
cover more than one type of hood within the same series, it may be that
reference is made to components that do not form part of the hood that youOperating instructions
are installing.The hood should be switched on at least as soon as cooking is tarted. Before
If evacuation is available (exhaust duct or air flue) we recommend using theusing the cooker hood please ensure that all plastic films like on metal grease
hood in the exhaust version to discharge all the kitchen vapours and odoursfilter is removed.
outdoors. Fittings can vary from country to country. We reserve the rightThe hood has the following controls (Fig. 4):
modify the product without any notice always with the aim of improvements1 - speed switch ? 2 - light switch
and in compliance with the relevant norms.The appliances is provided with microswitch, when the vapour flap is pulled
out, the light and motor turns on (if the light and motor switch is connected).
Exhaust version (Fig. 1)The hood turns off when the flap is closed please keep the chosen speed
The hood must be connected by the flange or the reduction (supplied as partstored.
of the hood) to a duct to vent all the exhausted air outside the kitchen. The
flange is designed to use ducts with no appreciable performance loss. OverMaintenance
horizontal areas, if any, the duct must be slanted about 10% upwards fromNOTE: Prior to any maintenance, switch off and disconnect from electrical
upstream to downstream.supply.
Note ? The efficiency of the exhaust hood decreases as the length of the1) Under normal cooking conditions the grease filter should be cleaned
ducts and number of elbows increase. When using the exhaust version,every 10-15 days in hot water, to which a suitable detergent has been
follow these rules: Do not connect the exhaust hood to chimneys, flues, andadded. For reasons of efficiency and safety regular cleaning is
air ducts serving the room.advised. The grease filter may be subject to a small amount of
Before venting into exhaust flues and ducts no longer in use, ask for theshrinkage initially.
approval of the person or agency responsible for the building. The evacu-2) The outer casing of the Cooker Hood should be cleaned with a damp
ated air must not be let into a warm air duct. For the evacuation of thecloth.
exhausted air please note official instructions.3) The effective life of the carbon filter will naturally depend on the
Suggestions for using the hood in exhaust positionfrequency and type of cooking fumes to which it is subject. As general
When an exhaust hood and a heat source requiring ambient air (e.g. gas,guide we suggest that a replacement is fitted at least every 12 months.
oil, coal stoves, etc.) are used at the same time, attention is required because4) Once a year, (more frequently with heavy usage), call a serviceman
the air necessary for combustion is exhausted from the room through theto clean the fan and air ducts to prevent build-up of flammable fat
hood and this creates depression. There is no such danger when thedeposits.
maximum depression in the room is 0,04 mbar. In this condition no exhaustNote: Vaporous and odours in the air are exhausted first through the grease
gas from the heat source is piped. To assure this condition, make openingsfilter and then (if the hood is in filter version) through the odour filter. The
in the room which cannot be closed (doors, windows, etc. are not sufficient)efficiency of the appliance depends on the condition of the filters. Clean the
and through which the air necessary for combustion can freely flow.outside of the hood with a sponge soaked with liquid neutral detergent or with
Note ? All the exhaust ductwork in the apartment or house should bea cloth soaked with denatured ethyl alcohol. Do not use products containing
studied. In case of doubts, get advice or authorisation from the person orabrasives.
agency responsible for the building. When using gas burners, gas ovens,Grease filter
etc. as well as when using the hood in the filter version, these precautionsThis absorbs vapour-suspended grease particles and protects the kitchen
are not necessary.and furniture from greasy residues. The filter should be washed every 10
Filter version (Fig. 2)to 15 days (in normal operating conditions). Dip the filter into a warm
This version is used when no exhaust duct to the outdoors is available. Thedegreaser solution.
air is purified by an active vegetable carbon filter and recycled into the room.Active carbon odour filter
Make sure the carbon odour filter is inserted.Attention: The filter should only be used in filter hoods. The exhausted air
The filter hood outlet flange must be connected to a duct, which passespasses through the active carbon filter and is cleaned. This filter cannot be
through the cabinet and discharges the filtered air.washed and must be replaced depending on how often the hood is used
(about twice a year).
InstallationCleaning or changing the grease filter (Fig.5)
Important: The cooker hood should not be operated until it isPull out the vapour flap (5/C), grab the opening tongue at the filter (5/D), and
completely mounted.take out the filter.
The hood must be mounted over the centre of the cooking area. The? Only for ADF 601 W : remove the retaining springs (5/E and clean the
minimum distances between the cooking area and the under part of the hoodfilter (5/F). Dip the filter into a warm degreaser solution do not wring the
is 650 mm. This hood is suitable to be use over a hob with 4 fireplaces.filter; press it in a cloth to dry.
Note ? The distances, however, are subject to the safety rules in effect? Only for ADF 602 G - ADF 60 E : Dip the filter into a degreaser solution
in the various countries.or put it in the dishwasher. Make sure not to damage the filter, which
Note ? Make sure the cabinet supports the weight of the hood.is made of several layers of thin alloy, by hitting or crushing it. The
Fastening only for ADF 601 Waluminium filter will may change colour, that will have no influence of the
Drill holes in the bottom and the out-let opening in the top of the cabinet usingefficiency of the filter, may it will improve it.
the enclosed jig. Make sure the front edge of unit B matches the measure-To reinstall it operates reversed.
ment of panel A of the cabinet. (Fig. 3) From the inside of the hood insert eightChanging the active carbon odour filter (Fig.6)
screws supplied with the hood. If the wall cupboard should be deeper than? Take off the grease filter as descripted mention above.
the appliance, a spacer (with depth as requested) can be fitted with screwsFor changing the carbon filter it is sufficient to turn if counter clockwise.
on the lower part of the hood.As the filter is an optional, the exhausting version can be easily converted
Fastening only for ADF 602 G - ADF 60 Eby the user into filtering version, following the above mentioned modalities
Cut the bottom and drill holes in the sides of the cabinet using the enclosedof the instructions-booklet.
template (Fig.3). Cut the out-let opening in the top of the cabinet using theChanging the bulbs (Fig. 6/G)
enclosed template. Insert the cooker hood into the cabinet until the two? To change the bulbs, it is sufficient to take off the lamp-cover (Fig.6/
retaining springs (Fig.3/A) are fixed into the previously drilled. From theG). Never use lamps with wattage higher than the one shown on the
inside of the hood insert six screws (Fig.3/B) supplied with the hood. If thelabel inside the hood.
sides of the cabinet are thicker than 16 mm and the cooker hood can not? Only for ADF 601 W : the bulbs must be only ?olive?-type
be installed due to the plastic spacer (Fig.3/B), please take off the spacer? Only for ADF 602 G - ADF 60 E : use only neon lamps
with aid of a tool. If the wall cupboard should be deeper than the appliance,
a spacer can be fitted with 2 screws into the 2 holes on the underside of theSafety rules
hood.Do not do any flambé cooking underneath the hood.
Fix the spigot reduction (Fig.1) onto the cooker hood 150-125 mm (supplied)When frying never leave the pan alone because the cooking oil could flare
and complete the exhaust ducting (not supplied) with diameter 150mm orup. Clean all the surfaces frequently to avoid danger of fire. To do so use
125 mm.a cloth and or brush soaked in denatured ethyl alcohol. It is also important
to remove and clean or substitute frequently the filter installed in the hood.
Electric connectionThis appliance is not intended for use by small children or infirm persons
Make sure the supply voltage ratings correspond with those stated on thewithout supervision. Young children should be supervised to ensure that
appliance data plate.they do not play with the appliance.
Attention: If the appliance does not have a plug, when making a fixedWarning: Exhaust air must not be discharged into any chimney or flue that
installation, a cut-off device must be used to assure omnipolar disconnectionmay carry combustion products from other sources. In addition, exhaust
of the mains. The cut-off distance of the contacts must be at least 3 mm.air must not be discharged into a wall cavity unless designed for the purpose.
If the appliance is provided with a supply cord and plug, the appliances must
be positioned so that the plug is accessible.
Attention: The manufacturers decline responsibility for problems caused by
failure to observe this rule.
For ADF 602 G - ADF 60 E
The wires in the supply cord are coloured as follows: |