4Gb33005.fm5 Page 11 Friday, August 24, 2001 9:51 AM
After-sales service
Before contacting After-Sales Specify:
Service:? The nature of the problem.
1. See if you can solve the problem ? The model.
yourself with the help of ? The service code (number
theTroubleshooting guide?).below the word SERVICE on the
2. Switch off the hood for a few rating plate inside the hood
minutes and re-start it to see if behind the grease filter).
the problem has cleared itself.? Your full address.
? Your telephone number and
3. If the malfunction persists, call area code.
After-Sales Service.
Installation
When installing the hood, the 2. Some models are fitted with Electrical connection
minimum distances from the a plastic deflector that
Before connecting the hood,
cooktop must be respected, closes off the rear outlet. If
and the numerical sequence fitted, remove it.make sure the voltage
indicated on the rating plate
and additional instructions
3. Fit the collar in the rear corresponds to the voltage in
must be followed exactly as outlet.your home.
indicated on the Installation
sheet.4. Put the cover (if fitted) in The plate is located inside
the upper outlet.the hood behind the grille.
External Exhaust ModeWarning!If the hood has a For GB this appliance is
carbon filter, this should be supplied without a plug and is
(A - see also installation
sheet)removed.intended for direct connection
to fixed wiring in accordance
Cooking fumes and vapours are Check that the switch inside the with national wiring
hood (if fitted) is in
conveyed outside through a regulations. An all-pole
duct connected to the hood by position?A? Extractor; if not, disconnection switch with a
set it to this position.
means of a collar.minimum contact separation
The outlet duct diameter of 3 mm must be included in
must be the same as that of Air Circulation Mode the fixed wiring in an easily
the collar.accessible position.
If a flue-damper is to be (F - see also installation The Manufacturer shall not
installed, check that it can sheet)be liable for any damage or
open and close freely when The air is filtered by a carbon problem arising from the
installation of the exhaust filter and recycled into the failure to comply with the
duct is complete.surrounding atmosphere. The above-mentioned
instructions.
The hood can be supplied filtered air is released towards
with one (upper) or two the kitchen ceiling.
(upper and rear) exhaust Warning!If the hood does
outlet holes.not have a carbon filter,
The hood is usually set up order one and fit it before
for using the upper exhaust use.
outlet.Check that the switch inside the
1. The collar must be seated in hood (if fitted) is in position
the upper exhaust outlet.?F? Filter; if not, set it to this
Use the rear exhaust outlet position.
(where present).
If the plug is provided, close off
1. Where fitted, remove the the upper exhaust hole.
cover closing off the rear
outlet and collar.
11 |