Important Safety Instructions
Read and Save These Instructions
Installation Must Comply With all Local Codes
Please Read Entire Instructions Before Proceeding
Safety Warning
WARNING
Turn off power circuit at service panel and lock out
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
panel before wiring this appliance.
OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:REQUIREMENT:
A. Use this unit only in the manner intended byWith internal blower: 120V AC, 60Hz. 15A Branch
the manufacturer. If you have questions, contactCircuit.
the manufacturer. (Bosch Service: 800-944-
With remote blower (DAH95 models only): 120V AC
2904.60Hz. 15A Dedicated Branch Circuit.
B. Before servicing or cleaning the unit, switch
Caution
power off at service panel and lock service
For general residential kitchen ventilating use only.
panel. This will prevent power from being
DO NOT use to exhaust hazardous or explosive
switched on accidentally. When the service
panel cannot be locked, securely fasten amaterials or vapors.
Caution
prominent warning device, such as a tag, to
Vent unit to the outside unless using recirculation kit.
the service panel.
Note: If using recirculation kit, refer to
C. Installation work and electrical wiring must be
instructions included with that unit.
done by qualified person(s) in accordance with
all applicable codes & standards, including fire-Warning
rated construction.
To reduce the risk of fire, use only metal ductwork.
D. Sufficient make-up air is needed for proper
combustion and exhausting of gases throughTools and Parts Needed:
the flue (chimney) of fuel burning equipment1. 1/2? Conduit w/ Connector
to prevent back-drafting. Follow the heating2. Blower (DAH95 models only)
equipment manufacturers guideline and safety3. Duct Cover (optional)
standards such as those published by the4. Ducting:
National Fire Protection Association (NFPA), thea) DAH93 and 94 models: 7? (8? is also accept-
American Society for Heating, Refrigeration andable, however a 7?-8? transition will also be
Air Conditioning Engineers (ASHRAE), and therequired)
local code authorities.b) DAH95 models with remote blower: 10? (7?-
E. Due to the size and weight of this unit, two10? transition is also needed. For horizontal
installers are recommended.discharge, a custom transition is required.)
5. R20 50W Incancescent Light Bulbs (2), installed
F. When cutting or drilling into wall or ceiling, do
(DAH93 models)
not damage electrical wiring or other hidden
6. 50W Par 20 Halogen Flood Light Bulbs (2), installed
utilities.
(DAH95 models)
G. To properly exhaust air, be sure to duct air7. Duct Tape
outside. Do not vent exhaust air into spaces
Parts Included:
within walls, ceilings, attics, crawl spaces, or
1. 4 #8 Sheetmetal Screws
garages.
2. Filters (30? models: 2, 36? models: 3)
H. Install this hood in accordance with all
3. Hood Canopy
requirements specified.
4. Remote Blower ?Pigtail? Adaptor (DAH95 models only)
I. Ventilator hood assembly models DAH93 and5. 7? Transition
DAH94 must be installed with blowers6. Spring Type Wire Nuts (rated for a minimum of (2)
DHG4001UC (included). Model DAH95 must#18ga wires and a maximum of 4 #14ga wires, UL &
be installed with integral blowers DHG4001UCCSA rated to 600V and 302o F/ 150o C.)
or DHG6001UC or remote blowers DHG6003UC7. Toggle Bolts (2)
or DHG1006UC. Other ventilator blowers8. 6 (30? models) or 12 (36? models) Blunt-Nosed
CANNOT be substituted.Sheetmetal Screws
This unit is approved for use with all residential appliances. For residential use only.
Note: The Bosch ventilation hood referred to throughout this manual is manufactured by BSH Home Appliances Corporation.
2 |