2016-3
? In the case of BLOOD TYPE, you can input a blood type (ABO)ALARM MODE
and Rh factor.
Current timeYou can set the hour and minutes for three
Viewing Identification Mode Dataseparate Daily Alarms. When the Daily Alarm is
In the Identification Mode, each press of C scrolls through the data in theMode indicatorturned on, the alarm sounds for 20 seconds at
sequence shown below.the preset time each day. Press any button to
stop the alarm after it starts to sound.
NAMEC CARDEMERGENCY NO.AB
When the Hourly Time Signal is turned on, the
P
watch beeps every hour on the hour.
BLOOD TYPEPASSPORTP? The mode indicator (ALM) indicates an alarm
MCscreen. SIG appears in place of ALM when
? In the Text Area, the title alternates with the input text.
the Hourly Time Signal screen is shown.
Hour : Minutes
Inputting Text and Numbers
Setting an Alarm Time
The following procedure is the same for NAME, C CARD,Alarm No.
1. In the Alarm Mode, press C to select the
EMERGENCY NO., and PASSPORT data.
alarm whose time you want to set.
Cursor1. In the Identification Mode, display the title of
the data you want to input.Alarm 1Alarm 2Alarm 3Hourly Time Signal
AB2. Hold down A until the cursor appears in the
text area.2. After you select an alarm, hold down A until the hour digits of the alarm
? If you do not want to input text into the texttime start to flash.
MCarea, press M 16 times to move the cursor? This operation automatically turns on the alarm.
to the number area and jump to step 7.3. Press M to move the flashing in the sequence shown below to select
3. Use B and C to change the character at the cursor position in the textother settings.
area. The character changes in the following sequence.HourMinutesOn/Off
Press C.Press B.
(space)A to Z1 to 0-4. While hour or minutes is flashing, press C to increase the setting or B
to decrease it.
? When the On/Off setting is flashing, press C to turn the alarm on
)(/.
(ON) and ofOFFf ( ).
4. When the character you want is at the cursor position, press M to move? When setting the alarm time using the 12-hour format, take care to
the cursor to the right.set the time correctly as a.m. (no indicator) or p.m. (P indicator).
5. Repeat the steps 3 and 4 until your text is complete.5. Press A to return to the alarm display screen.
6. After you input text, use M to move the cursor to the number area.
? The text area in the Identification Mode can hold up to 16 characters.Testing the Alarm
When the cursor is located at the 16th space of the text area, movingIn the Alarm Mode, hold down C to sound the alarm.
the cursor to the right causes it to jump down to the first digit in the
number area. When the cursor is at the 10th digit of the number area,Turning an Alarm On and Off
moving it to the right causes it jump back up to the first character of1. In the Alarm Mode, press C to select the alarm you want to turn on or off.
the text area.2. Hold down A until the hour digits of the alarm time start to flash.
7. Use B and C to change the character (hyphen, number, or space) at3. Press M twice to select alarm On/Off setting.
the cursor position in the number area. The character changes in the? Alarm On/Off setting is selected when the ON or OFF setting is
following sequence.flashing.
4. Press C to turn it on (ON) and ofOFFf ( ).
Press C.5. Press A to return to the alarm display screen.
x0 to 9(space)
? The alarm on indicator () is on the alarm display screen when the
Press B.
alarm is turned on.
8. When the character you want is at the cursor position, press M to move? In other modes (besides the Alarm Mode), the indicator remains
the cursor to the right.on the display as long as at least one of the alarms is on.
9. Repeat steps 7 and 8 until you complete number input.
10.Press A to store your data and return to the Identification Mode data
Turning the Hourly Time Signal On and Off
screen (without the cursor).
1. In the Alarm Mode, press C to select the
ABHourly Time Signal.
Inputting Your Blood Type
2. Hold down A until the ON indicator starts
1. In the Identification Mode, display theP
Rh factorto flash on the display in place of SIG.
BLOOD TYPE title.
3. Press C to turn it on (ON) and ofOFFf ( ).
Blood type ABO2. Hold down A until the blood type ABO startsMC4. Press A to return to the Hourly Time Signal
to flash.
display screen.
3. Use B and C to scroll through the available
? The hourly time signal on indicator ()
ABblood type in the following sequence.Hourly time signal
on indicatorappears on the display whenever the
Press C.
Hourly Time Signal is turned on.
MCABOAB
COUNTDOWN ALARM MODE
Press B.
4. Press M to advance to specification of the Rh factor.1/10 secondThe countdown timer can be set within a range
? At this time the current Rh factor (x or *) will flash on the display.of 1 second to 24 hours. When the countdown
5. Press C to select either x (negative) or * (positive).Mode indicatorreaches zero, an alarm sounds.
6. Press A to store your data and return to the BLOOD TYPE screen.? You can also select auto-repeat, which
automatically restarts the countdown from the
AB
Editing Identification Mode Data (except Blood Type Data)original value you set whenever zero is
1. In the Identification Mode, scroll through the data and display the onereached.
you want to edit.
2. Hold down A until the cursor appears in the text area.MCSetting the Countdown Time
3. Use M to move the cursor to the character you want to change.1. In the Countdown Alarm Mode, hold down
4. Use B and C to change the character.Hours : MinutesA until the hours digit of the countdown time
? For details on inputting characters, see OInputting Text and Numbers�starts to flash.
Seconds
(step 3 for text input and 7 for number).
5. After making the changes that you want, press A to store them and2. Press M to move the flashing in the sequence shown below to select
return to the Identification Mode data screen.other settings.
HoursMinutesSeconds
Deleting Identification Mode Data (except Blood Type Data)
1. In the Identification Mode, scroll through the data and display the one
3. While hours, minutes, or seconds digits are flashing, press C to increase
you want to delete.
the setting.
2. Hold down A until the cursor appears in the text area.
? To set the starting value of the countdown time to 24 hours, set
3. Press B and C at the same time to clear the data.
0:00 00.
? At this time the cursor appears in the text area, ready for input.
4. Press A to return to the countdown alarm display screen.
4. Input data or press A to return to the Identification Mode data screen. |