English
10. DMX addressing
Each ProWash LX utilises 14 channels of DMX 512 signal for complete control.
DMX addresses
To ensure that each projector accesses the correct signal, it is necessary to correctly address each fixture. Any number
between 1 and 499 can be generated via the multifunction panel of the ProWash LX.
This procedure must be carried out on every ProWash LX being used.
When initially powered up, each projector will show A001 indicating DMX address 1; a projector thus addressed will
respond to channels 1 to 14 from the DMX 512 controller; a second unit should be addressed as 17, a third as 33 and
so on until the final ProSpot LX, has been addressed.from the DMX 512 controller; a second unit should be addressed as
15, a third as 29 and so on until the final ProWash LX, has been addressed.
altering the dmx setting
1) Press the + or � buttons until the desired DMX address is displayed. The display will flash to indicate the selected address is not
stored in memory
AOO1+o�A013DMX 13 addressenterA013
selection of new DMX 512 address that,The unit reacts to new
DMX 512 address
if not confirmed, it flashes for 6 seconds
before going back to default (to the
address previously recorded)
2) Press the enter button to confirm your selection; the display will stop flashing and the projector will now respond to the
new DMX 512 setting.
3) To better understand the function of each channel, we refer you to section 12 ODMX 512 channel functions�.
Important Note: Keeping the + or � buttons pressed will cause the display to alter at increased speed, allowing a faster selec-
tion to be effected. |