English
11.2. Measure and test(MEAS)
The internal microprocessor of the Ispot 575 EB allows for several diagnostic and output parameters to be displayed.
You may record, in this menu, the position in which the projector will come to rest when turned on with no dmx signal attached.
AOO1
menu
FUNC+/-MEASenterTESTtestenter+/-PANenter0/255+/-
function testpan movement
+/-TILTenter0/255+/-
tilt movement
+/-DIMMenter0/255+/-
dimmer activation
+/-SHUTenter0/255+/-
shutter activation
+/-IRISenter0/255+/-
iris activation
+/-STZOenter0/255+/-
step zoom activation
+/-FOCUenter0/255+/-
focus activation
+/-GOB1enter0/255+/-
gobo wheel 1 selection
+/-GBP1enter0/255+/-
gobo 1 positioning
+/-GBR1enter0/255+/-
gobo 1 rotation
+/-GOB2enter0/255+/-
gobo wheel 2 selection
+/-GBP2enter0/255+/-
gobo 2 positioning
+/-GBR2enter0/255+/-
gobo 2 rotation
+/-PRISenter0/255+/-
prisma activation
+/-COL1enter0/255+/-
colour wheel 1 selection
+/-COL2enter0/255+/-
colour wheel 2 selection
+/-ZAP.E0/255+/-
enter
zap effect activation (the function depends on shutter
level, as per function with DMX 512 signal
+/-STORenterSUREenter
to record the position of the unit and of its internal
components. If DMX signal is not applied, the recorded
setting will appear at the end of reset operation when
the unit is switched on.
+/-TEMPtemperatureenter58C
to measure the internal temperaturein C°temperature measurement
+/-VFAN voltage to fansenter5.8V
to measure the DC voltage to the fans located in the unit. Valuesvoltage measurement
higher than 13,8V are anomalous.
+/-DMINDMX value on each channelenterCH01enter10
reading of DMX value (0/255), received by each of the 22from channel 1DMX value reading
channels on DMX 512 line.
+/-CH22enter255
to channel 22DMX value reading
+/-RATEDMX rateenter24.50
reading of DMX 512 signal value.value reading
+/-HOUR working timeenterLIFEenter10
working time (in hours)lamp life after last resetvalue reading
N.B.: reset the LIFE value when
changing the lamp
+/-LIFSenter589
life of all lampsvalue reading
used on the unit
+/-UNITenter1230
projector lifevalue reading |