" Do not place carbonated or fizzy drinks in the
freezer as it creates pressure on the container,DATOS T�CNICOS
Environment Protection
which may cause it to explode, resulting in
damage to the appliance.This appliance does not contain gasses which
Clase de eficienciaA
could damage the ozone layer, in either its
refrigerant circuit or insulation materials.TheCapacidad neta del frigorÃfico en litros260Installation
appliance shall not be discarded together with
" During normal operation, the condenser and
the urban refuse and rubbish. Avoid damagingConsumo energético en kWh/dÃa0,62
compressor at the back of the appliance heat up
the cooling unit, especially at the rear near the
considerably. For safety reasons, minimumConsumo energético en kWh/ano226
ventilation must be as shown in the relevantheat exchanger. Information on your local
Figure.disposal sites may be obtained from municipalDimensiones en mm
authorities.The materials used on this appliance
Attention: keep ventilation openings clear of
marked by the symbol are recyclable.Altura1400
obstruction.
Ancho550
" If the appliance is transported horizontally, it isDisposal of old Appliances
possible that the oil contained in the compressorProfundidad600
The symbol on the product or on its packaging
flows in the refrigerant circuit. It is advisable to
indicates that this product may not be treated as
wait at least two hours before connecting the
household waste. Instead it shall be handed over toLos datos técnicos se indican en la placa-matrÃcula situada sobre el lado izquierdo interno del aparato.
appliance to allow the oil to flow back in the
the applicable collection point for the recycling of
compressor.
electrical and electronic equipment. By ensuring this
product is disposed of correctly, you will help prevent" There are working parts in this product which
INSTALACI�N
heat up. Always ensure that there is adequatepotential negative consequences for the
ventilation as a failure to do this will result inenvironment and human health, which could
component failure and possible food loss. Seeotherwise be caused by inappropriate wasteConexión eléctrica
installation instructions.handling of this product. For more detailedAtención
Antes de enchufar el aparato, asegurarse de que la
" Parts which heat up should not be exposed.Se debe poder desenchufar el aparato; por lo tantoinformation about recycling of this product, please
tensión y la frecuencia indicadas en la tarjeta
Wherever possible the back of the product shouldmatrÃcula, correspondan a las de la instalaciónuna vez efectuada la instalación es necesario que elcontact your local city office, your household waste
be against a wall.disposal service or the shop where you purchased
doméstica. Se admite una oscilación del 6% sobreenchufe no quede escondido
the product.
" If the appliance has been transportedla tensión nominal.
horizontally, it is possible that the oil contained in
Para el funcionamiento a tensiones distintas, habráColocación
the compressor Ãlows in the refrigerant circuit. It
que utilizar un autotransformador de potencia
is advisable to wait at least two hours beforeSituar el aparato lejos de fuentes de calor, como:
adecuada. Asegurarse de que la toma de corriente y
connecting the appliance to allow tl?e oil to flowel enchufe sean compatibles entre sà sin tener queradiadores, estufas, exposición directa a los rayos
back in the compressor.del sol, etc.
interponer reducciones ladrones o adaptadores
varios. Si fuera necesario, cambiar la toma de laPor motivos de seguridad la ventilación debe ser
instalación de la casa.efectuada como se indica en la respectiva figura
CONTENTSEs indispensable conectar el aparato a una toma
Para aparato con mueble pénsil de encima, deberÃa
de tierra eficaz.
ser por lo menos de 100 mm (A).
Warnings 9Defrosting13Para ello el enchufe del cable de alimentación está
La solución preferible seria la ilustrada en la B (sin
Use 11Customer service and spare parts13dotado de un adecuado contacto. Si la toma demueble).
corriente de la instalación doméstica no estuviera
Technical information14Cleaning the interior 11
conectada a tierra, conectar el aparato a unaAtención: mantener las aperturas para la
Operation11
Installation14instalación de tierra, conforme a las leyes en vigor,ventilación libres de cualquier obstaculo.
Temperature regulation11
consultando para ello con un técnico especializado.
Fresh food refrigeration11Location14Dos patas graduables, situadas en la base del
Movable shelves11El fabricante declina toda responsabilidad en elmueble, consienten rivelarlo a la perfección.Electrical connection14
Positioning the door shelves11caso que esta norma no sea respetada.
Rear spacers15
Hints12Changing the opening direction of the door15Este aparato es conforme a las siguientes
Hints for refrigeration12Directivas Comunitarias:
Maintenance12- 87/308 CEE del 2/6/87 relativa a la supresión de
interferencias radio.
Periodic cleaning12
Periods of no operation12- 73/23 CEE 19/02/73 (Baja tensión) y
Interior light12modificaciones sucesivas;
- 89/336 CEE 03/05/89 (Compatibilidad
electromagnética) y modificaciones sucesivas.
107 |