Clearance to Side
Minimum clearance required to any combustible material to the side of the appliance must be 150mm.
Clearance to Shelves
Minimum clearance to the underside of a 150mm combustible shelf from the hearth must be 833mm, add 12.5mm to this
dimension for every 25mm increase in the depth of the shelf.
To Light the Appliance
Remove the Fret (controls cover) to gain access Press and turn the gas control knob anti-clockwise until the indicator dot is
opposite the IGN. Keep the gas control knob fully depressed.
Press and release the piezo igniter until the pilot flame situated on the left-hand sideeep of the burner has lit at both ports. K
the gas control depressed for a further 10 to 15 seconds.
Release the gas control and check that the pilot flame remains lit. RNoteefe (Fo: r to r coFinvg.enien 2 force. pilot position.
the unit can be operated with the pilot only, i.e. with the control knobs set in the IGN position).
Push in the gas control slightly and turn anti-clockwise so that the indicator dot is at the required setting. Replace the fret
(controls cover).
To turn off the appliance and pilot, turn the gas control clockwise from any position until the indicator dot is apposite OFF
IMPORTANT After turning off or if the pilot and the appliance goes out for any reason, wait for three minutes before
attempting to relight.
- 3 - |