3. Adjust the twin recording level of DN-780Rs. (Master/Slave switch set to OFF.)
16EXPANDED FUNCTION
4. Press the CD SYNC. button #5 of DN-T645/625 to display ONormal Copy�. And press the select knob !2 to set
Multiple units of the DN-T645/625 or other DENON products (DN-780R etc.) can be used together for longer playthe CD SYNC. mode. And press the Twin recording button of DN-780R.
and recording time, simultaneous recording and other functions.
5. Press the play/pause (13) button t of DN-T645/625. Recording starts all decks.
2 CASCADE (MULTIPULE CONTINUOUS) OPERATION6. Press the stop (2) button on one of the units. The all unit is also set to the stop mode.
Y Refer to figure 1 to connect the equipment.
Y Use a single RCA cable to connect the unitsO CASCADE OUT jacks with the unitsO CASCADE IN jacks.NOTES :
Y When the first and last units are connected as shown in figure 1, recording and playback are performedY Use tapes of the same times (lengths) as far as possible.
endlessly. Note that in the recording mode, previous recordings are overwritten.Y Note that the auto reverse timing is not synchronized.
Y If the first and last units are not connected, operation stops at the last unit.
Figure 1
Cascade playbackCascade recordingunit 1DN-T645
1. Load the discs and the tapes you want to play in all1. Load cassette tapes on which nothing is recording
the units. Make sure the Dolby NR and play modeinto decks of all the units and set the Dolby NR
are properly set.modes. Adjust the recording level for Decks.
2. Use the RELAY MODE switch !3 to set the relay2. Use the RELAY MODE switch !3 to set the relay
mode of all units to OCASCADE�.mode of all units to OCASCADE�.
3. Press the play/pause (13) button t on unit 1.3. Press the rec/rec mute (4) button @9 on Deck of all
Playback starts.the units.
Y Playback on CD ends, Deck starts playing.= Check that all Decks are set to the recording
Y Playback on Deck ends, playback starts on unitpause mode.
2Os CD.= Also set the direction of tape travel at this time.unit 2DN-T645
4. Playback stops when the stop button on the unit4. Press the Deck play (0 or 1) button @9 on unit 1.
currently playing is pressed.Recording starts.
Y Once recording on Deck ends, recording starts
NOTE :on Deck of the next unit.
Y The front and rear sides of the tape are playedY Deck is set to the recording pause mode on unit
continuously, regardless of the position of theon which recording has ended.
REV. MODE switch.= Cascade recording stops if Deck of any of the
units is set to anything other than the recording
pause mode.
5. Recording stops when the stop (2) button @9 on the
deck currently recording is pressed. After doing
this, press the stop (2) buttons @9 on all the decks.Figure 2DN-T645
NOTE :
Y The front and rear sides of the tape are recorded
continuously, regardless of the position of the
REV. MODE switch.
External synchronized recording
The synchronized recording can be use when the DN-T645/625 is used in combination with DENON other
product (DN-780R etc.).
LR
When the CD playerOs play/pause button and the deckOs play button are pressed, a synchronized signal for starting
is output from the EXT. SYNC. jack. When the stop buttons on the CD player and the deck are pressed aDN-780R
synchronized signal for stopping is output.
Y Refer to figure 2 to connect the equipment.
Y Use a single RCA cable to connect the unitsO EXT. SYNC. OUT jacks with the unitsO EXT. SYNC. IN jacks.
= Set the infrared remote sensors of all the units to OOFF� when using this function. Also set the same infrared
remote control codes for all the units. (Refer to OPRESET FUNCTIONS AND OPERATIONS� (See page 18).)RL
Failure to make these settings could result in malfunction.
1. Load the CD into DN-T645/625. Load unrecorded cassette tapes into all decks.
2. Set the reverse mode and Dolby NR of all decks.