NC
INSTALLATION
Adjustment to different types of gas
If a different type of gas from the one indicated ina
the plate is used, the cooking hob must be
adapted to it.
b
1. The gas nozzles must be changed by Customer
Service or a qualified technician.
Nozzles not supplied with the appliance must
be ordered from Customer Service.
2. Connect the cooking hob to the gas shutîoff
valvebymeans of apipesuitablefor thetypec
of gas used, in compliance with current local
regulations.
3. Adjust the minimum setting of the taps.
Note: when liquid petroleum gas is used �G 30/
G 31O, the minimum gas setting screws must be
tightened as far as they will go.
Replacing the injectors �see table in enclosed
product description sheetO
1. Remove gridsa .d
2. Extract burnersb .
3. Using a socket spanner of the appropriate size,e
c,unscrewtheinjectortobereplaced.
4. Replace it with the injector suitable for the newî
type of gas.
5. Reîassemble the injector ind .
6. For models equipped with a triple crown
burner, proceed as shown in figure.
xRemovethetwoscrewsffollowedbythe
capg then replace both injectorsd as
previously described.
Replace the capg, ensuring the seal is
properly positioned before attempting to use
the cooktop.
7. Before installing the cooktop, remember to affix
the gas calibration plate supplied with the
injectors in such a way that it covers the
existing information relating to gas calibration.
Adjusting minimum gas setting of
taps
To ensure that the minimum setting is correctly
adjusted, remove knobe and proceed as follows:
xtighten�îOtoreducetheheightoftheflame;
xloosen�+Otoincreasetheheightoftheflame.
The adjustment must be performed with the tap in
minimum gas setting position �small flameO .