Controls and Features (cont.)
Control Panel
1 23 4 5 6789p
TEMP
STAND BYOPERATELAMPEMERGENCYAVRGBSETTINGQUICK
ALIGN.
1STAND BY Indicator6EMERGENCY indicator
ON:When in stand-by mode.Blinking:Something abnormal has occurred with the
BlinkingWhen in cool-down mode.:projector.
CAUTIONSMemo
Y The cool-down mode continues for about 20 seconds, duringAbout the emergency mode:
which projection cannot�be started again. After the cooling-The emergency mode is shown when the following anomalies have
occurred with the projector (the EMERGENCY indicator blinks). In
down period, the projector goes into stand-by mode, but the
the emergency mode, projection is automatically interrupted and the
cooling fans will continue to run for about 10 minutes morecooling fans operate for about 10 minutes (except the cooling fan for
before they stop (exept the cooling fan for the light-sourcethe light-source lamp power supply which continues running as long
lamp power supply which continues running as long as theas the MAIN POWER switch is on).
MAIN POWER switch is on).Y When the light-source lamp has suddenly gone off.
Y When the fans have stopped.
Y The purpose of the cool-down mode is to prevent inner parts
Y When the temperature inside has risen abnormally high.
from being deformed or broken by heat from the heated lamp
as well as to prolong the life of the lamp. Do not turn off theCAUTION
main power switch while in the cool-down mode. Also, do
Y When an emergency mode is shown:
not block any of exhaust openings while in cool-down mode.
After the cooling fans (except the one for the light-source
2OPERATE indicator
ON: When the projector is in operation (projecting)lamp power supply) have stopped, turn off the main power
switch and unplug the power cord from the wall outlet.
3OPERATE buttonCheck that the filter covers are correctly installed. Then, plug
When the projector is in the stand-by mode, press thisin the power cord again and try operating the projector.
button for one or more seconds, and the main power switchIf it goes into an emergency mode again, after the cooling
is turned on, causing the OPERATE indicator to light.fans ha Pressve stopped, turn off the main power switch, unplug
it again, and the projector goes into the cool-down mode,the power cord, and call your dealer for repair.
then stand-by mode.
Memo
While in the cool-down mode:
If you press the OPERATE button, the projector is not tuned on.
4Lamp indicator
ON: After the light-source lamp has been used for
more than approx. 900 hours.
BlinkingReplace the lamp. (Ask the dealer where you:
purchased your projector to replace the lamp.)
5TEMP indicator
ON:The temperature inside the projector has
abnormally risen.
Note
Y While the TEMP indicator is on (during abnormal temperature), the
power is automatically cut off, and an emergency mode is shown
(with the EMERGENCY indicator blinking).
8