How to Use the External Control
About the External Control
The Multi-Format Monitor has two external control terminals.
One is the MAKE/TRIGGER terminal, which allows the monitor to be controlled by the MAKE (make contact) or TRIG. (trigger)
method selected in the function setting.
MAKE (make contact system): Controls the function by short-circuiting the corresponding pin terminal to the GND pin terminal, or
disconnecting (opening) it.
TRIG. (trigger system):Controls the function by inputting the pulse signal instantaneously to the corresponding pin terminal.
* MAKE or TRIG. are selected from OREMOTE SYSTEM� in SET-UP MENU.
The other terminal used for remote control is the RS-485 terminal, and this allows the monitor to be controlled by serial
communication.
NOTE:
Control priority is in the following order; 1 MAKE/TRIGGER terminal > 2 RS-485 terminal > 3 Front panel buttons or menu functions of the monitor.
Y When using the make contact system, you cannot use the functions which are applied to the MAKE/TRIGGER terminal operating the front panel
buttons or the menu of the monitor. (When using the trigger system you can also use those functions operating the monitor directly.)
Y When controlling the monitor using RS-485 terminal, you cannot use the functions operating the front panel buttons or the menu of the monitor
except turning on or off the monitor.
How to Use the MAKE/TRIGGER Terminal
Function of the MAKE/TRIGGER terminal To change the functions applied to the pin
The followings are the configurations and the functions of theterminals
pin terminals of RJ-45 connector. You can change the1. Display SET-UP MENU, then move the MENU control to
functions applied to the 1st to 6th pin terminals by setting / to select OREMOTE SYSTEM,� then move it to .
OREMOTE SYSTEM� of SET-UP MENU.
12 3 4 5 6 782. Move the MENU control to / to select OCONTROL
NO.Functions to be controlledFORM,� then move it to / to select OSET.�
1INP. AChanges the input to INPUT A3. Move the MENU control to / to select the number of
2INP. CChanges the input to INPUT C
3MARKERTurns on/off MARKERthe pin terminal (PORT F1 � PORT F6) you want to set,
4ASPECTChanges ASPECTthen move it to / to select the function.
5TALLYControls the tally lampNOTE:
6L. METERTurns on/off AUDIO LEVELYou cannot apply two or more functions to one terminal.
Caution:METER
This is a female7External control
connecter.8GND
Functions controlled by the MAKE/TRIGGER Terminal
DisplayFunctions to be controlledOpeningShort-circuiting*1
INP. AChanges the input to INPUT AInvalidValid
INP. BChanges the input to INPUT BInvalidValid
INP. CChanges the input to INPUT CInvalidValid
INP. DChanges the input to INPUT DInvalidValid
CO. OFFTurns on/off COLOR OFFOffOn (Monochrome screen)*2
MARKERTurns on/off MARKEROffOn*2
ASPECTChanges ASPECT4:316:9
MA. SELSelects the MARKER settingsSelects the settings without OR-�Selects the settings with OR-�*3
TALLYControls the tally lampOffOn*4, 5
TA. SELSelects the color of the tally lampGreenRed
STATUSTurns on/off the status displayOffOn
L. METERTurns on/off AUDIO LEVEL METEROffOn*6
*1 : The TRIG. (trigger) system switches each function by short-circuiting for approx. 1 second.
*2 : When selecting the TRIG. (trigger) system, these functions cannot be controlled if no signal is input.
*3 : Activates the settings of the items with OR-� or without OR-� in the OMARKER� menu. OMARKER� on page 12
*4 : This function do not work if you set OFORMAT IND.� in OFUNCTION SETTING� of SET-UP MENU to OON.�
*5 : Tally lamp Control and External control (the 7th pin terminal) can be controlled by the MAKE (make contact) system even when you select the
OTRIG.� (trigger) system.
*6 : This function works only when using the Multi-Format SDI Unit (option).
Operation
1. Short-circuit the 7th pin terminal (External control) to the 8th pin terminal (GND) so that the monitor can be controlled by the
external control.
2. When selecting the OMAKE� (make contact) system, operate each function by short-circuiting the corresponding pin
terminal to the 8th pin terminal (GND) or opening it.
When selecting the OTRIG.� (trigger) system, operate each function by Pulse control, that is short-circuiting the
corresponding pin terminal to the 8th pin terminal (GND) for about 1 second.
NOTES:
Y When controlling INP. A/B/C/D, only one terminal must be short-circuited. (Other terminals must be opened.)
Y When selecting the OTRIG.� (trigger) system, you can operate only one function at a time. Operate the functions one by one.
19
EN14-24_LCT1811-001A-H.p651905.5.13, 1:54 PM |