SAFETY AREA/R-SAFETY AREA R-Y PHASE
Displays dotted lines to indicate the areas corre-Sets the R-Y phase.
sponding to 80%, 88%, or 90% of the screen size
Y 90/92/94/112
(the aspect ratio setting in OASPECT SELECT/R-
ASPECT SELECT�). R/B GAIN
OFF: SAFETY AREA does not function.Sets the R/B gain.
90%: Marked area is 90% of the 16:9 screen ratio.Y 0.86/0.56/0.68/0.79
88%: Marked area is 88% of the 16:9 screen ratio.
G-Y PHASE
80%: Marked area is 80% of the 16:9 screen ratio.
Sets the G-Y phase.
NOTES:
Y 244/253/236/240
Y When a picture of 4:3 aspect ratio is input, SAFETY AREA for 4:3
screen is displayed.
G/B GAIN
Y To display SAFETY AREA for 16:9 screen ratio when a picture of
Sets the G/B gain.
16:9 aspect ratio is input, set OMARKER SELECT/R-MARKER
SELECT� to OFF. (In this case, setting of ASPECT SELECT isY 0.30/0.34/0.40/0.45
invalid.)
R-Y PHASE90
R/B GAIN0.79
ITU601
G-Y PHASE244
COLOR MATRIX
G/B GAIN0.45
Selects or adjusts the standard of the colour
R-Y PHASE90
demodulation (colour rendering).
R/B GAIN0.86
Press the button to
<COLOR MATRIX>ITU709
display the setting menuG-Y PHASE244
SELECT :MANUAL
illustrated on the right.R-Y PHASE : 90
R/B GAIN :0.86G/B GAIN0.30
G-Y PHASE : 244
G/B GAIN :0.36
sub menu
reset
EXIT: MENU ADJUST:- + SELECT:
The menu screen when
MANUAL is selected.
I The standard setting is set to OITU601� or OITU709�
depending on the input signal format.
The factory preset of MANUAL is ITU709
Input Signal FormatStandardManual
settingsetting
(MANUAL)
NTSC, PAL, 480/60i,
ITU601
480/60p, 576/50i, 575/50p
ITU709
720/60p, 1080/50i, 1080/60i,
ITU709
1035/60i, 1080/24psF
SELECT
Selects the picture matrix standard.
ITU601 or ITU709 : Standard setting
MANUAL: Manual setting
NOTE :
The following items are displayed when MANUAL is selected.
When ITU601 or ITU709 is selected, they are not displayed.
17