Table of AUTO OFF Error messages
VTR operation
Counter displayMonitor displayDescription
(Restart condition)
CAP ROTATE TOOCAP ROTA TOOIf the capstan motor speed is abnormally low, the
STOP
AUTO OFF lamp lights, and the message display
SLOWSLOW
(POWER OFF ? ON)
flashes.
CAP TENSION ERRORCAP TENSION ERRORIf an abnormal tension at the supply side is detected
STOP
in the capstan mode, the AUTO OFF lamp lights, and
(POWER OFF ? ON)
the message display flashes.
DEWDEWIf condensation is detected, the AUTO OFF lamp
lights, the message display flashes, and the VTR is
transferred to the eject mode. After the tape is
ejected, the drum rotates in order to eliminate the
condensation.
When the condensation has been eliminated, the EJECT
AUTO OFF lamp and message display go off, and (Normal operation
the VTR can be used.resumed after
<Notes>condensation is
1)If condensation is detected in the eject mode, the eliminated)
drum starts rotating as soon as it is detected.
2)If condensation is detected when the cassette
has been inserted, the drum rotation is stopped,
and after the tape is ejected, the drum starts
rotating.
DRUM ROTATE TOODRUM ROTA TOOIf the cylinder motor speed is abnormally high, the
STOP
AUTO OFF lamp lights, and the message display
FASTFAST(POWER OFF ? ON)
flashes.
DRUM ROTATE TOODRUM ROTA TOOIf the cylinder motor speed is abnormally low, the STOP
AUTO OFF lamp lights, and the message display
SLOWSLOW(POWER OFF ? ON)
flashes.
E-FFE-FFIf the tape start and tape end are detected simulta-STOP
neously either during or after loading, the AUTO OFF
(POWER OFF ? ON)
lamp lights, and the message display flashes.
The AUTO OFF lamp lights and the message display
FRONT LOAD ERRORFRONT LOAD ERROR
flashes when the take-up reel has been rotating idly
for a fixed period of time while the start/end STOP
processing operation during loading (half position) is (POWER OFF ? ON)
being performed or when it was impossible to eject
the tape.
If the cassette does not move up even when 6
FRONT LOAD MOTORFRONT LOAD MOTOR
seconds have elapsed since the VTR was transferred
to the eject mode, the AUTO OFF lamp lights, and
the message display flashes.
STOP
<Note>
If the cassette does not move down inside the (POWER OFF ? ON)
machine even when 6 seconds have elapsed since
the cassette was inserted, the VTR is transferred to
the eject mode.
LOADING MOTORLOADING MOTORWhen the unloading operation is not completed within
6 seconds, the AUTO OFF lamp lights, and the
message display flashes.
STOP
<Note>
(POWER OFF ? ON)
When the loading operation is not completed within 6
seconds, the VTR is transferred to the eject (unload-
ing) mode.
� 91 � |