Connector signals
PARALLEL I/O (50P) connector
(1)PULSE SIGNAL: The signal fall is detected and the signal becomes active.
Pin no.SignalDirectionTypeDescription
1REC COMMANDINPUTPULSE SIGNALWhen this signal becomes active simultaneously with the
play command, it transfers the VTR to the REC PLAY
mode. However, the VTR is not transferred to the REC
mode if the insert or assemble mode has been set.
2PLAY COMMANDINPUTPULSE SIGNALThis transfers the VTR to the PLAY mode.
3FF COMMANDINPUTPULSE SIGNALThis transfers the VTR to the FF mode.
4REW COMMANDINPUTPULSE SIGNALThis transfers the VTR to the REW mode.
5STOP COMMANDINPUTPULSE SIGNALThis transfers the VTR to the STOP mode.
6STBY ONINPUTPULSE SIGNALWhen the VTR is in the loosing or STBY OFF mode, it is
COMMANDset to the STNBY ON mode as soon as it receives this
command.
7STBY OFFINPUTPULSE SIGNALWhen the VTR is in the loosing or STBY ON mode, it is
COMMANDset to the STNBY OFF mode as soon as it receives this
command.
8RS-422 REMOTEINPUTPULSE SIGNALThis enables RS-422 control. However, the VTR must be
ON COMMANDin the REMOTE mode for this command to take effect.
9RS-422 REMOTEINPUTPULSE SIGNALThis disables RS-422 control.
OFF COMMAND
10LOCAL ENABLEINPUTPULSE SIGNALThis enables the REMOTE OP MAP functions. When the
COMMANDMAP MODE is set to ALL, it also enables EJECT.
11EJECT COMMANDINPUTPULSE SIGNALThis transfers the VTR to the EJECT mode.
12ENTRYINPUTPULSE SIGNALWhen this signal has become active, the VTROs current
COMMANDtime (TC, CTL) is entered on the following menus:
When the VTR has opened the HOME menu:
eThe time is entered in CUE TIME on the HOME menu.
When the VTR has opened the AUTO EDIT menu:
eThe time is entered in CUE TIME on the HOME menu.
eThe time is entered at the IN point on the AUTO EDIT
menu.
When the VTR has opened the EXTEND MULTI CUE
menu:
eThe time is entered at the cursor position of the EXTEND
MULTI CUE menu.
When the VTR has opened the MULTI CUE menu:
eThe time is not entered on any of the menus.
When the VTR has opened a menu other than the ones
above:
eThe time is entered in CUE TIME on the HOME menu.
13ALL_REC_INH_INPUTPULSE SIGNALThis selects ALL as the REC INH menu setting.
ON COMMAND
14PRE_CTL_INH_INPUTPULSE SIGNALThis selects PRE_CTL as the REC INH menu setting.
ON COMMAND
15LOCAL DISABLEINPUTPULSE SIGNALThis disables the REMOTE OP MAP functions.
COMMANDWhen the MAP MODE is set to ALL, it also disables
EJECT.