AJ-HPX3000G(VQT1D27)E.book 60 2T87887437E
Setting the Time Code
Regeneration function using REC REVIEW
1Position the DISPLAY switch at [TC].
If the menu option FIRST REC TC is set to PRESET, if the
2Position the TCG switch at [SET].time code has been set or reset, or if the time code has
been switched from free run to Rec run, it is possible to
3Set the menu option TC MODE to ?DF? or ?NDF?. ?DF? regenerate the time code as the last time code of a clip
steps the time code in drop frame mode, and ?NDF?
recorded on the P2 card.
steps it in non-drop frame mode. However, the
This action requires you to preset the RET SW menu
camera always operates in ?NDF? for 24P, 24PA and
option on the SW MODE screen to R. REVIEW and the
24PN (Native) modes.
REC REVIEW REGEN menu option on the TC/UB screen
The menu option TC MODE can be found in the <TC/
to ON.
UB> screen, which is accessible from the MAIN
OPERATION page. 1Make sure the P2 card to record the data. To
regenerate the time code of the last recorded clip
? Note
when more than one P2 card is inserted, press the
Switching between DF and NDF is operative only
Thumbnail button to open the thumbnail screen.
when the system frequency of the camera-recorder is
set to 59.94 Hz.
2Be sure a P2 card is inserted for recording the clip
displayed at the end of the screen, and then switch
4Use the CURSOR buttons to set the time code.
the slot with the USER button assigned the SLOT
The time code setting range extends from
SEL function so that data will be recorded on the P2
00:00:00:00 to 23:59:59:29 (59.94 Hz), 23:59:59:23
card.
(24PN) or to 23:59:59:24 (50 Hz).
! button:Shifts the target (blinking) digit to the right.3Press the RET button on the lens. The message ?TC
" button:Shifts the target (blinking) digit to the left.REGEN? is displayed in the viewfinder. During the
# button:Advances the blinking number by one digit. next recording, the time code of the last recorded clip
$ button:Winds back the blinking number by one digit.on the card will be regenerated.
? Notes
5Change the position of the TCG switch.
zWhen a card with recorded data is changed, the
[F-RUN] steps the time code in free run mode, and [R-
time code of the last recorded clip on the changed
RUN] set it in recording run mode.
P2 card will be regenerated.
zThis function is disabled during recording or free-
? Notes
run.
zWhen the unit is in the 24P or 24PA mode, time
code settings are adjusted to the five-frame unit.
For 24PN (Native) mode, it is adjusted for countingTime code function during battery replacement
by the four-frame unit. The time code cannot be set
Even during battery replacement, the backup mechanism
when recording in the 24P, 24PA, and 24PN
functions, allowing the camera-recorder to operate
(Native) formats.
continuously.
zWhen the TCG switch is positioned at [SET],
If SYSTEM MODE is changed, a free-run time code may
thumbnails cannot be manipulated.
shift. After turning on the power again, confirm the time
code and reset if necessary.
Regeneration of Time Code
? Note
When the TGC switch is positioned to R-RUN, the time
When the POWER switch has been switched ON # OFF
code recorded on the last frame of the last recorded clip
# ON, the backup accuracy of the time code in free run
(with the latest recording date) on the P2 card is read, and
mode is about ?2 frames.
this time code can be used again.
When the menu option FIRST REC TC is set to REGEN
and a P2 card is removed or inserted or the target
recording card is changed with the USER button for the
SLOT SEL function, the same time code is added to the
last recorded clip on the target P2 card. When there is no
recorded clip, the time code is recorded on the new
recording target P2 card, from the value generated by the
TC generator built into the camera-recorder.
The menu option FIRST TC REC can be found in the <TC/
UB> screen, which is accessible from the MAIN
OPERATION page.
Adjustments and Settings for Recording : Setting Time Data
60 |