Error messages (continued)
If OT&S&M� is selected in the setup menu No. 008 (DISPLAY SEL), a message appears in the mode display whenever a
warning or error occurs. When multiple events occur, the event with the highest priority is displayed.
PriorityDisplayDescription
Error messagesWhen an operational malfunction has occurred in the unit, the error number flashes andHigh
(See error message table)the error message is indicated on the counter display.
When SG has been selected as the input signal by the INPUT SELECT button, the OINT
INT SGSG� display will appear for the first two seconds at the start of operation (E-E mode)
when the REC button is pressed.
If there are no input signals--with the exception of the analog audio signals--supplied to
the connectors selected by the INPUT SELECT button, the ONO INPUT� display will
NO INPUT
appear for the first two seconds at the start of operation (E-E mode) when the REC
button is pressed.
Warning messagesWhen a warning occurs in this unit, the error number and warning message are
indicated on the counter display.
(See error message table)LowWhen multiple warnings occur, the warning with the highest priority is displayed.
UMID information display
This is displayed when UMID information is present on the input signal in E-E mode.
This lamp lights during tape playback when UMID information has been recorded on the tape. ONO-INFO� is displayed when
there is no UMID information.
DisplayDescription
MATNO Material number
COPYInstance number (No. of copies)
OWNRCountry, organization, user
Reception status from GPS satellites when recording spatial coordinates (height above sea level,
longitude and latitude):
HOLD : No reception from any satellite
POS2D : Reception possible, but number of satellites is insufficient. Height above sea level will not
be accurate.
3D : Good reception
DATEDate
TIME UTC (Coordinated Universal Time) and time difference with UTC