Controls and their functions
Left Side PanelOperation panel
;:< 78 9G H I
1 2 3 4 5 6D E F
BREAKERMAINACOUT(200VA)ALARM
12OVAC 80HzRESETCCU
> = <? @ ;:=?@B CJK L
>A
: Cable clamp1 VF power switch [VF POWER]
This is used to clamp the optical fiber cable from theThis is used to set the viewfinderOs power to ON or OFF.
CCU.When it is lighted, the viewfinderOs power is OFF.
; Optical fiber connector2 Front tally ON/OFF switch [FRONT TALLY]
OPT FIBER connector (EDW.3K.93C.CLC made by LEMO)This is used set the viewfinder and lens tally lamp to ON
Pin No. FunctionPolaritySignal flowor OFF. When the lamp is lighted, the tally lamp is OFF.
1Optical fiberCAM#CCU
3 CENTER marker switch [CENTER MARKER]
This is used to set the center marker to ON or OFF. 2Optical fibeCCU#CAM
3Control wire, hot+CAM!#CCU
4Control wire, cold�CAM!#CCU4 CURSOR switch
5AC 240V live+CCU#CAMThis is used to set the cursor on the viewfinder screen to
ON or OFF. When it is lighted, the cursor is OFF.6AC 240V neutral�CCU#CAM
< AC outlet5 Cursor memory switch 1
An AC output of up to 200 VA can be supplied to thisIf this switch is held down while the cursor switch is ON,
outlet.the current cursor status is stored in the memory. If the
cursor switch is set to ON after the cursor memory switch
= AC outlet circuit-breaker1 has been pressed, the cursor which was stored in the
This is the circuit-breaker for the AC outlet. If the ACmemory by the cursor memory switch 1 can be called.
output load is too high and the circuit breaker has been
tripped, reduce the load, and then reset the circuit6 Cursor memory switch 2
breaker by pressing the circuit breaker button.If this switch is held down while the cursor switch is ON,
the current cursor status is stored in the memory. If the
> Power main circuit breakercursor switch is set to ON after the cursor memory switch
This is the main circuit-breaker for the unit's power2 has been pressed, the cursor which was stored in the
supply. If the circuit breaker has been tripped by anmemory by the cursor memory switch 2 can be called.
overcurrent or for some other reason, check the cause,
take the appropriate measures to remedy the problem,7 H-POSI control [H-POSI]
and then reset the circuit breaker by pressing the circuitThis is used to adjust the horizontal position of the
breaker button.cursor.
? AC OUTLET reset switch8 V-POSI control [V-POSI]
This cuts off the AC output when it drops below theThis is used to adjust the vertical position of the cursor.
minimum voltage that can be supplied. When this has
happened, the outlet can be reset by pressing this reset9 Width control [WIDTH]
switch without turning off the camera's power.This is used to adjust the width of the cursor.
@ AC OUT alarm display: Height control [HEIGHT]
This lights when the AC output voltage range exceeds 10%.This is used to adjust the height of the cursor.
6 |