HOW TO USE EXTERNAL
CONTROL
ABOUT EXTERNAL CONTROL
The Multi-Format Monitor has two external control terminals.
ENGLISH
One is the MAKE/TRIGGER terminal, which allows the monitor to be controlled by the MAKE(make contact) or TRG. (trigger
contact) method selected in the function setting.
MAKE (make contact system): Controls the function by stable disconnection (terminal open) or short-circuiting (short with GND of
15th terminal) of the controlled terminal.
TRG. (trigger system): Controls the function by instantaneously (one second) short-circuiting (short with GND of 15th
terminal) the controlled terminal.
* MAKE or TRIGGER are selected from REMOTE SYSTEM in the setup menu.
* The 14th terminal (REMOTE ENABLE) is always controlled by the make contact system regardless of the REMOTE SYSTEM
setting.
The other terminal used for remote control is the RS-232C terminal. This allows the monitor to be controlled by a PC via serial
communication.
NOTE: Control priority is in the following order; 1 MAKE/TRIGGER terminal > 2 RS-232C terminal > 3 front panel buttons.
When trigger contact is on, the front panel buttons can be operated.
HOW TO USE THE MAKE/TRIGGER TERMINAL109876
54 3 2 1
Connections
Connect (short-circuit) the 15th terminal (GND) to each of the 1st through 14th terminals in the 3-line
15-pin D-sub connector. The functions of each terminal are listed below.
The Names and Functions of Terminals15 14 13 12 11
No. NamesFunctionsOperations (OFF p[ ON)*1
1TALLYPuts on the tally lamp.Put offPut on
2INPUT AChanges the input to INPUT ANot changeChange
3INPUT BChanges the input to INPUT BNot changeChange
4INPUT CChanges the input to INPUT CNot changeChange
5INPUT DChanges the input to INPUT DNot changeChange
6INPUT EChanges the input to INPUT ENot changeChange
7INPUT FChanges the input to INPUT FNot changeChange
8COLOR OFFChanges the picture black-and-white. Not changeChange
9AREA MARKERDisplays the area marker.Not displayDisplay
10ASPECTChanges the screen ratio to 16:94:316:9
11TALLY SELECTSwitch the tally lamp color.GREENRED
12MARKERSelects the type of the area markerSelection in the main unit Selection in the remote*2
control
13STATUSDisplays the monitorOs statusDisplay*3
14REMOTE ENABLE Makes the external control form theInvalidValid*4
MAKE terminal valid or invalid
15GNDUsed as a ground terminal��
*1 : OFF stands for disconnection, and ON stands for short-circuit.
When trigger contact is on, the setting switches between ON and OFF every time the terminal is short-circuited.
(Only TALLY is controlled by being OFF(disconnection) and ON(short-circuit).)
*2 : Selects the area marker size from AREA MARKER (setting on the main unit) or AREA MARKER-R (setting on the remote control) setting.
*3 : The STATUS function is activated when the connection to the STATUS terminal is changed (ON to OFF, or OFF to ON). The monitorOs status is displayed for 3
seconds.
*4 : Setting REMOTE ENABLE to ON enables remote control. (same for both MAKE/TRIGGER methods.)
Operation
1. Set REMOTE ENABLE to ON.
2. Short-circuit or disconnect the desired terminal. (When trigger contact is on, duration of short-circuit is approx. 1 second.)
Changing the Signal Input
1. Set REMOTE ENABLE to ON.
2. Short-circuit the desired INPUT terminal. (When trigger contact is on, duration of short-circuit is approx. 1 second.)
3. Disconnect the INPUT terminal selected above. The signal input is actually changed after the disconnection has been
completed.
NOTES: Y When more than two terminals are selected (short-circuited) from INPUT A through INPUT F, the signal input is not changed.
To control INPUT A through INPUT F, we recommend using the interlock switch, which turns off a switch when another switch is turned on.
Y When trigger contact is on, and if several terminals are short-circuited simultaneously, proper control cannot be done. It is always
necessary to short-circuit one terminal for one operation. Also, use of the Tact Switch is recommended.
19