CARE AND MAINTENANCE
Cleaning the Indoor Unit and Remote Air Purifying Filters Pre-season Inspection
Control Is the discharged air cold/warm?
Y Wipe gently with a soft, dry cloth.Operation is normal if 15 minutes after the start of
Y Do not use water hotter than 40uC or polishing fluidoperation, the difference between the air intake and
1
to clean the unit.outlet vents temperature is:-
Raise the
Cleaning the Air Filterfront panel
(Recommendation:- If the unit is operated in a dustyCooling Model
environment, clean the filters every two weeks,
continuous use of this dirty filters will reduce coolingSolar RefreshingCOOL � 8!C or above
or heating efficiency)Deodorizing Filter
Heat Pump Model
1Remove dirt using a vacuum cleaner.Catechin Air
2Wash back of the air filter with water.Purifying FilterCOOL � 8!C or above
HEAT � 14!C or above
Remove the air filters3If badly soiled, wash it with soap or a mild household2
detergent. Are the air intake or outlet vents of the indoor or
outdoor units obstructed?
4Let it dry and reinstall it.
Be sure the OFRONT� mark is facing you. Are the remote control batteries weak? Solar Refreshing Deodorizing Filter
* Damaged air filter.If the remote control display appears weak, replaceY Used to remove unpleasant odour and deodorize
Consult the nearest authorized dealer.the batteries.
the air in the room.
Part No.: CWD001049. When the Air Conditioner is Not Used
Y Reusable.Y Do not use benzene, thinner, scouring powder or
clothes soaked in caustic chemical to clean the unit.Y Vacuum, place under direct sunlight for 6 hours andfor an Extended Period of Time
fit it back in place.
Cleaning the Front Panel1To dry the internal parts of the indoor unit, operate(Recommended : every 6 months)
(Must be removed before washing)the unit for 2 - 3 hours using:-
1Raise the front panel higher than the horizontal and Catechin Air Purifying FilterCooling Model
pull to remove it.Y The filter is coated with catechin to prevent growth
of bacteria and viruses.
2Gently wash with water and a sponge.FAN operation
Y Reusable.
Y Do not press the front panel too hard when washing.
Y When use kitchen cleaning fluid (neutral detergent),Y Vacuum and fit it back in placeHeat Pump Model
rinse throughly.(Recommended : every 6 months)
Y Do not dry the front panel under direct sunlight.COOL operation with 30!C
3To fix the front panel, raise the front panelY Recommended to change these filters every 3 years.set temperature
horizontally, match the protruding portion on theDo not reuse damaged filters.2Turn off the power supply and unplug.
indoor unit to the fulcrum and push into place.Consult the nearest authorized dealer to purchase aNote: If the unit is not switched off by the remote
new filter.control, it will start operating when you plug in
Catechin Air Purifying Filter No.: CZ-SF70P(because the unit is equipped with Auto Restart
Solar Refreshing Deodorizing Filter No.: CZ-SFD70PControl).
3Remove the remote control batteries.
Y If you operate the air conditioner with dirty filters:-
�Air is not purified Recommended Inspection
Fulcrum�Cooling capacity decreasesY After used over several seasons, the unit will
�Foul odour is emittedbecome dirty and thus decreases the unitOs
performance. Depending on the operation
conditions, a dirty unit may produce odour and dust
may pollute dehumidification system. Therefore, a
seasonal inspection is recommended in addition to
Protruding portion on indoor unitregular cleaning. (Consult an authorized dealer).
HELPFUL INFORMATIONENERGY SAVING AND OPERATION
HINTS
Auto Operation Button Auto Restart Control
Y If power is resumed after a power failure, the
Setting the Temperature
ECONOMYECONOMYECONOMYECONOMYPOPOPOPOWERFULWERFULWERFULWERFULPOPOPPOOWERWERWWERERSLEEPSLEEPSLEEPSLEEPTIMERTIMERTIMERTIMERoperation will restart automatically after 3 - 5 1/2Y Approximately 10% of electricity can be saved.
minutes.Y Set the temperature higher or lower than the
Y Raise the front panel and press.Y Operation will be restarted automatically under thedesired temperature.
previous operation mode and airflow direction when
power is resumed as the operation is not stopped
Automatic Operationby the remote control.
Y If the remote control fails to function or has beenCooling Model
misplaced, press the Auto Operation button to start Timer Setting
the Automatic operation.Y When power failure occurs, the timer setting will beCooling Operation : 1!C higher
Y The Automatic operation will be activatedcancelled. Once power is resumed, reset the timer.
immediately once the Auto operation button isHeat Pump Model
pressed. However, temperature cannot be adjusted Thunder and Lightning
in this operation.Y This air conditioner is equipped with a built-in surgeCooling Operation : 1!C higher
Y The power indicator on the indoor unit will blink untilprotective device. However, in order to furtherHeating Operation : 2!C lower
the operation mode is selected automatically.protect your air conditioner from being damaged by
Y To cancel this operation, press once more.abnormally strong lightning activity, you may switch
off the main power supply and unplug from power Air Filters and Air Purifying Filters
Remote Control Signal Receiving Soundsocket.Y Clean the air filters every 2 weeks and the Air
Y To switch off the beep (Signal Receiving Sound),Purifying Filters every 6 months.
press the Auto Operation button for 10 secondsY Dirty filters may reduces cooling or heating
continuously or longer.efficiency.
OBeep�, Obeep� sound will be heard at the tenth
seconds. Keep All Doors and Windows Closed
Note: OBeep� sound will be heard at the fifthY Otherwise, cooling or heating performance will be
seconds;reduced and electricity cost is wasted.
However please press continuously until you
heard Obeep�, Obeep� sound. Outdoor Unit
Y Repeat the above steps if you want to switch on theY Do not block the air outlet vents. Otherwise, it will
Signal Receiving Sound.lower the cooling or heating performance.
(This is for Servicing purposes only.) Timer and Sleep Mode
Note: If you press this button continuously for 5 to 10Y To prevent wastage of electricity, use sleep mode
seconds, Test Run operation will be performed.when sleeping or Timer when going out.
A Obeep� sound will be heard at the fifth seconds
indicating the Test Run starts to operate. Avoid Direct Sunlight
Y Keep curtains or drapes closed to avoid direct
sunlight during cooling operation. |