Installation
How to Install the Unit
1. To prevent vibration and noise, make sure
the unit is installed securely and firmly
Fence
2. Install the unit where the sunlight does not
Awning
shine directly on the unit.
Cooled air
3. The outside of the cabinet must extendHeat
radiation
outward for at least 12" and there should
be no obstacles, such as a fence or wall,
within 20" from the back of the cabinet
because it will prevent heat radiation of theAbout 1/2"
condenser.Over 20"
30"~60"
Restriction of outside air will greatly reduce
the cooling efficiency of the air conditioner.
CAUTION : All side louvers of the cabinet must remain exposed to the outside of the
structure.
1
4. Install the unit a little slanted so the back is slightly lower than the front(about /2").
This will force condensed water to flow to the outside.
5. Install the unit with the bottom about 30"~60" above the floor level.
Window Requirements
NOTE: All supporting parts should be secured to firm wood, masonry, or metal.
This unit is designed for installation in
27" to 39"
standard double hung windows with actual
16" min
opening widths from 27" to 39".Stool
(With frame curtain)
Offset
The top and bottom window sash must open
FeaturesandInstallation11
/2" to 1/4"
sufficiently to allow a clear vertical opening of
16" from the bottom of the upper sash to the
Sill
window stool.
Exterior
Interior wall
23 5/8" min.
(Without frame curtain)
10 |