4 Lift the dustbag holder out of the� Replace the Activated Carbon Filter every 6
appliance.(fig.24)months or when you notice that smell
absorption becomes less effective.
Make sure you hold the dustbag upright when
lifting it out of the appliance.1 To replace the Activated Carbon Filter, see
5 Remove the full dustbag from the holder bythe Motor Protection Filter section above.
pulling the cardboard tag.(fig.25)Instead of cleaning the filter, you have to
When you do this, the dustbag will beinsert a new filter.
automatically sealed.
Motor Outlet Filter
6 Slide the cardboard tag of the new dustbag
into the two grooves of the dustbag holder asThe AFS Micro Filter located in the back of this
far as possible. Re-insert the dustbag holderappliance will filter a large part of the smallest
into the vacuum cleaner.(fig.26)particles from the exhaust air by means of its
electrostatically charged fibres.
You cannot close the cover if no dustbag has 1 Replace the AFS Micro Filter every six
been inserted.months
� If provided, you can use the cotton dustbag2 Open the filter grille.(fig.29)
instead of paper dustbags.The cotton dustbag
can be used and emptied repeatedly.3 Remove the old filter.(fig.30)
4 Insert the new filter into the appliance.
Ordering dustbags
Philips s-baga paper dustbags are available under5 Close the filter grille and push the left and
right bottom corners until they snap
type number FC8021 (482248010113).home.(fig.31)
Philips s-baga clinic high filtration dustbags are
available under type number FC8022HEPA filter
(883802201010).
Instead of with the AFS Micro Filter, this appliance
Philips cotton dustbags are available under typecan also be equipped with the special HEPA Filter.
number FC8020 (432200493291).The HEPA Filter is able to remove at least 99.99%
of all particles down to 0.0003 mm in size from
Cleaning and replacing filtersthe outlet air.This not only includes normal house
dust, but also harmful microscopic vermin such as
Motor Protection Filterhouse dust mites and their excrements, which are
Every time you empty or replace the dustbag,well-known causes of respiratory allergies.
clean the Permanent Motor Protection Filter.
1 Replace the HEPA Filter as soon as the pilot
1 Remove the dustbag holder with the dustbag.light of the filter-full indicator goes on
(specific types only).The HEPA filter can be
2 Take the Motor Protection Filter holder outreplaced in the same way as the AFS Micro
of the appliance and clean the filter by shakingFilter.(fig.32)
it over a dustbin.(fig.27)
3 Press the filter holder with the clean filterOrdering filters
firmly into place to ensure that it fits properlyAFS Micro Filters are available under type
at the bottom.(fig.28)number FC8030 (432200492910).
4 Place the dustbag holder with the dustbagHEPA Filters are available under type number
back into the appliance.FC8031 (432200492920).
Activated Carbon FilterActivated Carbon Filters are available under type
number FC8033 (482248020145).
Instead of with the Motor Protection Filter, someActivated Carbon upgrade kits are available under
appliances are equipped with an Activatedtype number FC8034.
Carbon Filter.This filter neutralises smells
produced by the dirt in the dustbag.
8 |